FireCADCalc

Heat Exchanger Exergy Destruction and Its Annual Cost

Entropy generated and exergy destroyed by heat transfer across a finite temperature difference in a heat exchanger, and the annual cost of that lost work.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Feedwater heater 0.5 MW/K, 400 to 440 K, steam side 450 K constant (450 to 449.9)Cryogenic precooler 20 kW/K, 150 to 200 K, hot 210 to 160 K

Accepted: 0.001 to 1,000,000 kW/K
Accepted: -173.15 to 1,226.8 °C
Accepted: -173.15 to 1,226.8 °C
Accepted: -173.15 to 1,226.8 °C
Accepted: -173.15 to 1,226.8 °C
Accepted: -73.15 to 56.85 °C
Accepted: 0 to 10,000,000
Accepted: 0 to 100 %
Accepted: 0 to 10,000,000

Results

Only the irreversibility of heat transfer across the finite temperature difference is counted (no pressure-drop or mixing losses).

Heat duty20.000MW
Thermodynamic mean temperature, hot449.95K
Thermodynamic mean temperature, cold419.68K
Entropy generation3,205.7W/K
Exergy destruction955.78kW
Annual cost of exergy destruction474,068

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Feedwater heater 0.5 MW/K, 400 to 440 K, steam side 450 K constant (450 to 449.9). The inputs, in the units selected above:

InputValue
Cold stream heat capacity rate500.00 kW/K
Cold inlet126.85 °C
Cold outlet166.85 °C
Hot inlet176.85 °C
Hot outlet176.75 °C
Surroundings (dead state) temperature25.000 °C
Capital cost of equipment per kW of exergy (any currency)800.00 -
Annual interest (capital charge) rate12.000 %
Energy cost per kW-year (same currency)400.00 -

Applying the formula below gives:

ResultValue
Heat duty20.000 MW
Thermodynamic mean temperature, hot449.95 K
Thermodynamic mean temperature, cold419.68 K
Entropy generation3,205.7 W/K
Exergy destruction955.78 kW
Annual cost of exergy destruction474,068

Open this example in the calculator and change any input.

Formula

\(\dot S_{irr} = q\left(\frac{1}{T_{lm,c}} - \frac{1}{T_{lm,h}}\right), \quad T_{lm} = \frac{T_o - T_i}{\ln(T_o/T_i)}\)

\(\dot I = T_0\dot S_{irr}, \quad C = \dot I\,(c_{eq}r + c_q)\)

Variables

Symbol Meaning SI unit
\(C_c\) Cold stream heat capacity rate W/K
\(T_{c,i}\) Cold inlet K
\(T_{c,o}\) Cold outlet K
\(T_{h,i}\) Hot inlet K
\(T_{h,o}\) Hot outlet K
\(T_0\) Surroundings (dead state) temperature K
\(c_{eq}\) Capital cost of equipment per kW of exergy (any currency) -
\(r\) Annual interest (capital charge) rate -
\(c_q\) Energy cost per kW-year (same currency) -
\(q\) Heat duty W
\(T_{lm,h}\) Thermodynamic mean temperature, hot K
\(T_{lm,c}\) Thermodynamic mean temperature, cold K
\(\dot S_{irr}\) Entropy generation W/K
\(\dot I\) Exergy destruction W
\(C\) Annual cost of exergy destruction -

Method and standards

Second-law (Gouy–Stodola) analysis of heat transfer.

Where it is used

  • Comparing approach temperatures in heat recovery networks.
  • Teaching second-law costs of heat exchange.

Common mistakes

  • Using the arithmetic mean instead of the log mean of absolute temperatures.
  • Using °C in the entropy terms.

Assumptions and limits

  • Constant specific heats; heat transfer irreversibility only.

Questions and answers

Why does a smaller ΔT cost capital but save exergy?

Exergy destroyed falls roughly in proportion to ΔT/T², but the area needed rises as 1/ΔT; the optimum balances the two.

Why is it significant near ambient temperature?

Exergy destruction scales with T₀/T; at low absolute temperatures (refrigeration) each kelvin of approach is far more costly.

What do the defaults represent?

An illustrative case: Feedwater heater 0.5 MW/K, 400 to 440 K, steam side 450 K constant (450 to 449.9). Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Shah and Sekulić, Fundamentals of Heat Exchanger Design (Wiley, 2003), sec. 11.4, eqs. 11.30, 11.55 and 11.64 and Example 11.9

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.