Agitator Power from Power Number

Shaft power of a stirred tank agitator from the impeller power number, speed, diameter and liquid density, with Reynolds number, tip speed and power per volume.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textileTank and drum

Inputs

Examples: Rushton turbine Np 5, 120 rpm, 0.6 m, waterHydrofoil Np 0.35, 90 rpm, 1 m, 1 100 kg/m³, 5 cPPitched blade Np 1.3, 300 rpm, 0.25 m, 50 cP oil

From the impeller maker's or published curve at your Reynolds number.

Results

Ungassed power; gassing and solids change the power number. Add drive losses to size the motor.

Impeller Reynolds number720,000
Shaft power3.1104kW
Shaft torque247.52N·m
Tip speed3.7699m/s
Liquid volume4.5804m³
Power per unit volume0.67906kW/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Rushton turbine Np 5, 120 rpm, 0.6 m, water. The inputs, in the units selected above:

InputValue
Power number of the impeller5.0000 -
Impeller speed120.00 rpm
Impeller diameter0.60000 m
Liquid density1,000.0 kg/m³
Liquid viscosity1.0000 cP
Tank diameter1.8000 m
Liquid height1.8000 m

Applying the formula below gives:

ResultValue
Impeller Reynolds number720,000
Shaft power3.1104 kW
Shaft torque247.52 N·m
Tip speed3.7699 m/s
Liquid volume4.5804 m³
Power per unit volume0.67906 kW/m³

Open this example in the calculator and change any input.

Formula

\(Re = \frac{\rho N D^2}{\mu}, \quad P = N_p \rho N^3 D^5\)

\(M = \frac{P}{2\pi N}, \quad u_{tip} = \pi N D, \quad V = \frac{\pi T^2}{4} H\)

Variables

Symbol Meaning SI unit
\(N_p\) Power number of the impeller -
\(N\) Impeller speed 1/s
\(D\) Impeller diameter m
\(\rho\) Liquid density kg/m³
\(\mu\) Liquid viscosity Pa·s
\(T\) Tank diameter m
\(H\) Liquid height m
\(Re\) Impeller Reynolds number -
\(P\) Shaft power W
\(M\) Shaft torque N·m
\(u_{tip}\) Tip speed m/s
\(V\) Liquid volume m³
\(P/V\) Power per unit volume W/m³

Method and standards

The power number collects the impeller geometry; in the turbulent range it is constant, so power varies with ρN³D⁵.

Where it is used

  • Sizing agitator motors and gearboxes.
  • Scaling up mixing from a pilot vessel.
  • Checking whether a mixer is loaded as expected.

Common mistakes

  • Using the turbulent power number at low Reynolds numbers.
  • Forgetting gassed power is lower and ungassed higher.
  • Sizing the motor without drive losses.

Assumptions and limits

  • Single impeller; baffled tank for the quoted power numbers. Unbaffled tanks (vortexing, Froude-number dependence) and multiple impellers on one shaft are outside scope: the power number entered must already account for them.

References

  • Rushton
  • Costich and Everett (1950)
  • power characteristics of mixing impellers

Questions and answers

What power does a 0.6 m Rushton turbine take at 120 rpm in water?

With N_p 5, 3.1 kW at the shaft; Reynolds number 720 000, fully turbulent.

Why does power rise so fast with size?

P goes with N³D⁵: doubling the diameter at the same speed needs 32 times the power.

What power per volume is typical?

About 0.1 kW/m³ for gentle blending up to 1–2 kW/m³ for dispersion; the example gives 0.68 kW/m³.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.