Worked example
Example: 10 m³, 2 kmol/m³, k 1/h, 100 kJ/mol. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Reacting volume | 10.000 m³ |
| Initial concentration, in kmol/m³ (= mol/L; not mol/m³) | 2.0000 - |
| First-order rate constant at the operating temperature | 1.0000 1/h |
| Heat of reaction (released) | 100.00 kJ/mol |
| Overall coefficient | 400.00 W/(m²·K) |
| Reaction temperature | 80.000 °C |
| Mean coolant temperature | 30.000 °C |
| Time into the batch | 1.0000 h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Peak heat release (at t = 0) | 555.56 kW |
| Cooling area needed | 27.778 m² |
| Heat release at time t | 204.38 kW |
| Heat released up to t | 351.18 kWh |
| Conversion at t | 63.212 % |
Open this example in the calculator and change any input.
Formula
\(Q_0 = (-\Delta H_r)kC_{A0}V, \quad A = \frac{Q_0}{U(T_r - T_c)}, \quad Q(t) = Q_0e^{-kt}, \quad X = 1 - e^{-kt}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Reacting volume | m³ |
| \(C_{A0}\) | Initial concentration, in kmol/m³ (= mol/L; not mol/m³) | kmol/m³ |
| \(k\) | First-order rate constant at the operating temperature | 1/s |
| \(-\Delta H_r\) | Heat of reaction (released) | J/mol |
| \(U\) | Overall coefficient | W/(m²·K) |
| \(T_r\) | Reaction temperature | K |
| \(T_c\) | Mean coolant temperature | K |
| \(t\) | Time into the batch | s |
| \(Q_0\) | Peak heat release (at t = 0) | W |
| \(A\) | Cooling area needed | m² |
| \(Q(t)\) | Heat release at time t | W |
| \(E(t)\) | Heat released up to t | J |
| \(X(t)\) | Conversion at t | - |
Method and standards
First-order heat release.
Where it is used
- Jacket and coil sizing.
- Safety review of batch charges.
Common mistakes
- Sizing on the average duty.
- Ignoring the rise of k with temperature.
Assumptions and limits
- Isothermal; first order; all charged at start; the reactor is held at T_r (no heat accumulation).
- The concentration is entered as a number in kmol/m³ (the same number as mol/L); a value in mol/m³ would be 1000 times too large.
References
- Batch reactor energy balance for first-order kinetics (Levenspiel, Chemical Reaction Engineering, 3rd ed. (Wiley, 1999), ch. 9; Fogler, ch. 13)
Questions and answers
Why is the peak at the start?
With all reactant charged, the first-order rate is highest when concentration is highest.
How can the peak be cut?
Feed one reactant gradually (semi-batch), start colder, or dilute.
What do the defaults represent?
10 m³ at 2 kmol/m³ with a one-hour time constant and 100 kJ/mol released.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.