Worked example
Example: SCR catalyst. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Feed flow at reference conditions | 5,000.0 m³/h |
| Catalyst bed (or reactor) volume | 2.5000 m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Space velocity | 2,000.0 1/h |
| Space time V/V̇₀ | 1.8000 s |
Open this example in the calculator and change any input.
Formula
\(SV = \frac{\dot V_0}{V}, \quad \tau_s = \frac{V}{\dot V_0}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V_0\) | Feed flow at reference conditions | m³/s |
| \(V\) | Catalyst bed (or reactor) volume | m³ |
| \(SV\) | Space velocity | 1/s |
| \(\tau_s\) | Space time V/V̇₀ | s |
Method and standards
Definitions.
Where it is used
- Catalytic reactors, SCR and hydrotreaters.
- Ion exchange and adsorber beds (bed volumes per hour).
Common mistakes
- Actual instead of reference flow.
- Bed volume vs reactor volume.
Assumptions and limits
- Uniform bed.
- With zero flow the space time is unbounded and is not shown.
References
- Definitions SV = V̇₀/V
- τ = V/V̇₀ (Fogler)
Questions and answers
5000 m³/h through 2.5 m³ of catalyst?
GHSV 2000 /h, space time 1.8 s.
Why reference conditions?
So reactors at different pressures and temperatures compare.
SCR and deNOx catalysts?
Makers quote GHSV ranges for their catalyst.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.