FireCADCalc

Gas–Liquid Reaction: Hatta Number and Enhancement Factor

Hatta number and enhancement factor for absorption with a fast pseudo-first-order reaction in the liquid, the regime, and the enhanced absorption flux.

Thermal power plantDistillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Fast CO2–amine-likeSlow reactionInstantaneous limit (D_B given)

Enables the instantaneous-reaction limit E_i; leave 0 to skip it.

Results

Pseudo-first-order: the liquid reactant is not depleted near the interface. Enter D_B to check against the instantaneous-reaction limit 1 + D_BC_B/(νD_AC_Ai). Film theory.

Hatta number21.213
Enhancement factor21.213
Regime (1 slow, 2 intermediate, 3 fast)3.0000
Absorption flux (kmol/(m²·s))4.2426e-05

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Fast CO2–amine-like. The inputs, in the units selected above:

InputValue
Second-order rate constant (m³/(kmol·s))5,000.0 -
Liquid-phase reactant concentration (kmol/m³)0.50000 -
Diffusivity of the dissolved gas in the liquid1.8000e-09 m²/s
Liquid-side mass-transfer coefficient1.0000e-04 m/s
Interface concentration of the gas (kmol/m³)0.020000 -
Diffusivity of the liquid reactant (0 if unknown)0 m²/s
Moles of liquid reactant per mole of gas absorbed1.0000 -

Applying the formula below gives:

ResultValue
Hatta number21.213
Enhancement factor21.213
Regime (1 slow, 2 intermediate, 3 fast)3.0000
Absorption flux (kmol/(m²·s))4.2426e-05

Open this example in the calculator and change any input.

Formula

\(Ha = \frac{\sqrt{k_2C_BD_A}}{k_L}, \quad E = \min\left(\frac{Ha}{\tanh Ha},\ E_i\right), \quad E_i = 1 + \frac{D_BC_B}{\nu D_AC_{Ai}}, \quad N_A = Ek_LC_{Ai}\)

Regime: slow for \(Ha < 0.3\), intermediate for \(0.3 \le Ha \le 3\), fast for \(Ha > 3\).

Variables

Symbol Meaning SI unit
\(k_2\) Second-order rate constant (m³/(kmol·s)) -
\(C_B\) Liquid-phase reactant concentration (kmol/m³) -
\(D_A\) Diffusivity of the dissolved gas in the liquid m²/s
\(k_L\) Liquid-side mass-transfer coefficient m/s
\(C_{Ai}\) Interface concentration of the gas (kmol/m³) -
\(Ha\) Hatta number -
\(E\) Enhancement factor -
\(\text{regime}\) Regime (1 slow, 2 intermediate, 3 fast) -
\(N_A\) Absorption flux (kmol/(m²·s)) -
\(D_B\) Diffusivity of the liquid reactant (0 if unknown) m²/s
\(\nu\) Moles of liquid reactant per mole of gas absorbed -
\(E_i\) Instantaneous-reaction enhancement -

Method and standards

Film theory, pseudo-first order.

Where it is used

  • Amine and caustic scrubbers.
  • Gas–liquid reactor selection.

Common mistakes

  • Ignoring reactant depletion (instantaneous regime).
  • Using gas-side k_G for k_L.

Assumptions and limits

  • Pseudo-first order; film theory.
  • Without D_B the instantaneous limit is not applied and E can be overstated at high Ha. With D_B entered, E is limited to E_i, and a note warns when Ha exceeds E_i/2, where reactant depletion makes the pseudo-first-order value too high.

References

  • Levenspiel
  • Chemical Reaction Engineering
  • 3rd ed. (Wiley, 1999)
  • ch. 23 (fluid–fluid reactions: Hatta number and enhancement factor)
  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 14 (absorption with chemical reaction)

Questions and answers

What does the Hatta number mean?

Reaction rate in the liquid film against diffusion through it: below 0.3 the reaction happens in the bulk; above 3 within the film, and absorption speeds up.

Why does it matter for design?

In the fast regime the interfacial area governs, so packing or spray area matters; in the slow regime liquid holdup does.

What do the defaults represent?

CO₂ into an amine-like solution with a fast second-order reaction.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.