FireCADCalc

Height of a Transfer Unit from Film Coefficients

Gas- and liquid-film heights of a transfer unit from fluxes and volumetric coefficients, the overall HTU, and packed height for a number of transfer units.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Dilute absorberStripper λ > 1

kmol/(m²·s); use the same kmol basis as the coefficients.
kmol/(m²·s); use the same kmol basis as the coefficients.
kmol/(m³·s)
kmol/(m³·s)

Results

Dilute systems with constant molar flows. Get N_OG from the Colburn calculator; film coefficients from packing correlations or vendor data.

Gas-film HTU0.50000m
Liquid-film HTU0.18750m
mG/L0.30000
Overall gas HTU0.55625m
Packed height3.3375m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Dilute absorber. The inputs, in the units selected above:

InputValue
Gas molar flux, kmol/(m²·s)0.030000 -
Liquid molar flux, kmol/(m²·s)0.15000 -
Gas-film coefficient, kmol/(m³·s)0.060000 -
Liquid-film coefficient, kmol/(m³·s)0.80000 -
Equilibrium slope (y = mx)1.5000 -
Overall gas transfer units6.0000 -

Applying the formula below gives:

ResultValue
Gas-film HTU0.50000 m
Liquid-film HTU0.18750 m
mG/L0.30000
Overall gas HTU0.55625 m
Packed height3.3375 m

Open this example in the calculator and change any input.

Formula

\(H_G = \frac{G_m}{k_ya}, \quad H_L = \frac{L_m}{k_xa}, \quad H_{OG} = H_G + \frac{mG_m}{L_m}H_L, \quad Z = H_{OG}N_{OG}\)

Variables

Symbol Meaning SI unit
\(G_m\) Gas molar flux -
\(L_m\) Liquid molar flux -
\(k_ya\) Gas-film coefficient -
\(k_xa\) Liquid-film coefficient -
\(m\) Equilibrium slope (y = mx) -
\(N_{OG}\) Overall gas transfer units -
\(H_G\) Gas-film HTU m
\(H_L\) Liquid-film HTU m
\(\lambda\) mG/L -
\(H_{OG}\) Overall gas HTU m
\(Z\) Packed height m

Method and standards

Two-film theory.

Where it is used

  • Absorber and stripper sizing.
  • Scrubber height checks.

Common mistakes

  • Mixing mass and molar fluxes.
  • Using coefficients for another packing size.

Assumptions and limits

  • Dilute; straight equilibrium line.
  • Fluxes and coefficients are plain numbers in kmol/(m²·s) and kmol/(m³·s), with no unit lists; they must share the kmol basis, or the HTU is out by a factor of 1000.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 14 (H_OG = H_G + λH_L)

Questions and answers

Why add λ·H_L to H_G?

The overall resistance is the gas film plus the liquid film seen from the gas side; the liquid part is scaled by the slope mG/L.

What HTU is typical?

0.3–1 m for random packing in absorption; less for structured packing.

What do the defaults represent?

A dilute gas absorber with mostly gas-film control.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.