FireCADCalc

Distillation Condenser and Reboiler Duties from Reflux

Vapour and liquid flows in both column sections and the condenser and reboiler duties from distillate, reflux ratio, feed condition and molar latent heats.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: D 40, F 100 kmol/h, R 2, liquid feedHalf-vapour feed

Results

Reflux80.000kmol/h
Vapour to the condenser120.00kmol/h
Liquid in the stripping section180.00kmol/h
Boil-up120.00kmol/h
Condenser duty1,066.7kW
Reboiler duty1,266.7kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: D 40, F 100 kmol/h, R 2, liquid feed. The inputs, in the units selected above:

InputValue
Distillate40.000 kmol/h
Feed100.00 kmol/h
Reflux ratio L/D2.0000 -
Feed condition q1.0000 -
Latent heat of the overhead vapour32.000 kJ/mol
Latent heat of the bottoms38.000 kJ/mol

Applying the formula below gives:

ResultValue
Reflux80.000 kmol/h
Vapour to the condenser120.00 kmol/h
Liquid in the stripping section180.00 kmol/h
Boil-up120.00 kmol/h
Condenser duty1,066.7 kW
Reboiler duty1,266.7 kW

Open this example in the calculator and change any input.

Formula

\(L = RD, \quad V = (R + 1)D, \quad L' = L + qF, \quad V' = V - (1 - q)F, \quad Q_C = V\lambda_D, \quad Q_R = V'\lambda_B\)

Variables

Symbol Meaning SI unit
\(D\) Distillate mol/s
\(F\) Feed mol/s
\(R\) Reflux ratio L/D -
\(q\) Feed condition q -
\(\lambda_D\) Latent heat of the overhead vapour J/mol
\(\lambda_B\) Latent heat of the bottoms J/mol
\(L\) Reflux mol/s
\(V\) Vapour to the condenser mol/s
\(L'\) Liquid in the stripping section mol/s
\(V'\) Boil-up mol/s
\(Q_C\) Condenser duty W
\(Q_R\) Reboiler duty W

Method and standards

Section balances with constant molar overflow.

Where it is used

  • Utility sizing for columns.
  • Steam and cooling water budgets.

Common mistakes

  • Using mass latent heats with molar flows.
  • Ignoring feed vapour.

Assumptions and limits

  • Total condenser; saturated reflux.
  • Inputs that give a negative stripping liquid L' or boil-up V' are rejected.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 13 (distillation)
  • constant molar overflow and feed condition

Questions and answers

Why does a vapour feed cut the reboiler duty?

Vapour in the feed adds to the rectifying section, so less boil-up is needed: V' = V − (1 − q)F.

Are latent heats molar?

Yes, in J/mol; constant molar overflow assumes they are nearly equal.

What about sensible heat?

Neglected; add it for subcooled reflux.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.