Worked example
Example: Sub-cooled feed. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Feed enthalpy | 150.00 kJ/kg |
| Saturated liquid enthalpy at feed-plate pressure | 200.00 kJ/kg |
| Saturated vapour enthalpy | 1,000.0 kJ/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Feed condition q | 1.0625 |
| Share vaporised (0–1 for a two-phase feed) | -0.062500 |
| q-line angle from the horizontal | 86.634 ° |
Open this example in the calculator and change any input.
Formula
\(q = \frac{h_V - h_F}{h_V - h_L}, \quad \text{slope} = \frac{q}{q - 1}, \quad \theta = \arctan(\text{slope}),\ 0 \le \theta < 180^\circ\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(h_F\) | Feed enthalpy | J/kg |
| \(h_L\) | Saturated liquid enthalpy at feed-plate pressure | J/kg |
| \(h_V\) | Saturated vapour enthalpy | J/kg |
| \(q\) | Feed condition q | - |
| \(1 - q\) | Share vaporised (0–1 for a two-phase feed) | - |
| \(\theta\) | q-line angle from the horizontal | rad |
Method and standards
Definition.
Where it is used
- Column design and feed preheat decisions.
- Examinations.
Common mistakes
- Enthalpies at different pressures.
- Sign of the slope.
Assumptions and limits
- Constant molal overflow.
- The angle is measured anticlockwise from the +x axis and given between 0° and 180°: a part-vaporised feed (0 < q < 1) has a q-line falling to the right, for example 135° at q = 0.5.
References
- q = (H_V − h_F)/(H_V − h_L); q-line slope q/(q − 1) (McCabe–Thiele)
Questions and answers
Sub-cooled feed, 50 kJ/kg below boiling, latent 800 kJ/kg?
q = 1.0625: the q-line leans steeply right.
Saturated vapour feed?
q = 0: a horizontal q-line.
Why does q matter?
It changes liquid and vapour flows below the feed and so the reflux needed.