FireCADCalc

Absorber Theoretical Stages (Kremser Equation)

Number of theoretical stages of a counter-current absorber with a straight equilibrium line (y = mx) from the gas inlet and outlet and liquid inlet, by Kremser.

Sugar mill and cogenerationRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Clean solvent, A = 1.5Lean solvent with solute, A = 1.25A below 1, modest recovery

Results

Dilute systems with straight operating and equilibrium lines; round the stages up and divide by the tray efficiency.

Absorption factor L/(mG)1.5000
Theoretical stages4.9139
Fraction of solute absorbed95.000%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Clean solvent, A = 1.5. The inputs, in the units selected above:

InputValue
Solute in the gas entering (mole fraction)2.0000 %
Solute in the gas leaving0.10000 %
Solute in the liquid entering0 %
Equilibrium slope y = mx1.2000 -
Liquid-to-gas molar ratio1.8000 -

Applying the formula below gives:

ResultValue
Absorption factor L/(mG)1.5000
Theoretical stages4.9139
Fraction of solute absorbed95.000 %

Open this example in the calculator and change any input.

Formula

\(N = \frac{\ln\left[\frac{y_{in} - m x_{in}}{y_{out} - m x_{in}}\left(1 - \frac{1}{A}\right) + \frac{1}{A}\right]}{\ln A}, \quad A = \frac{L}{mG}\)

Variables

Symbol Meaning SI unit
\(y_{in}\) Solute in the gas entering (mole fraction) -
\(y_{out}\) Solute in the gas leaving -
\(x_{in}\) Solute in the liquid entering -
\(m\) Equilibrium slope y = mx -
\(L/G\) Liquid-to-gas molar ratio -
\(A\) Absorption factor L/(mG) -
\(N\) Theoretical stages -
\(\phi\) Fraction of solute absorbed -

Method and standards

Kremser.

Where it is used

  • Scrubbers and absorbers.
  • Strippers (with the stripping form).

Common mistakes

  • Mass instead of molar L/G.
  • Non-linear equilibrium.

Assumptions and limits

  • Dilute, isothermal, straight lines.
  • For A within 10⁻⁶ of 1 the linear A = 1 form is used, which avoids a loss of precision in the general formula.

References

  • Kremser (1930) equation for counter-current stages with constant absorption factor A = L/(mG)

Questions and answers

2 % to 0.1 %, clean solvent, m 1.2, L/G 1.8?

A = 1.5: about 4.91 theoretical stages.

Why must A exceed a minimum?

With too little liquid the outlet target can never be reached.

A = 1?

A separate linear form applies; the calculator uses it.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.