Worked example
Example: 2 % to 0.1 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Solute in the gas entering | 2.0000 % |
| Solute in the gas leaving | 0.10000 % |
| Solute in the liquid entering | 0 % |
| Equilibrium slope y = mx | 1.2000 - |
| Liquid-to-gas molar ratio | 1.8000 - |
| Height of a transfer unit | 0.60000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Stripping factor mG/L | 0.66667 |
| Transfer units | 5.9773 |
| Packed height | 3.5864 m |
Open this example in the calculator and change any input.
Formula
\(N_{OG} = \frac{1}{1 - \lambda}\ln\left[(1 - \lambda)\frac{y_1 - m x_2}{y_2 - m x_2} + \lambda\right], \quad \lambda = \frac{mG}{L}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(y_1\) | Solute in the gas entering | - |
| \(y_2\) | Solute in the gas leaving | - |
| \(x_2\) | Solute in the liquid entering | - |
| \(m\) | Equilibrium slope y = mx | - |
| \(L/G\) | Liquid-to-gas molar ratio | - |
| \(H_{OG}\) | Height of a transfer unit | m |
| \(\lambda\) | Stripping factor mG/L | - |
| \(N_{OG}\) | Transfer units | - |
| \(Z\) | Packed height | m |
Method and standards
Colburn.
Where it is used
- Packed scrubbers and strippers.
- Flue gas and vent scrubbers.
Common mistakes
- Mass ratios for molar.
- H_OG outside the packing's range.
Assumptions and limits
- Dilute, isothermal, straight lines.
References
- Colburn (1939) N_OG for straight equilibrium and operating lines; Z = H_OG × N_OG
Questions and answers
2 % to 0.1 % with m 1.2 and L/G 1.8, H_OG 0.6 m?
N_OG about 5.98: some 3.6 m of packing.
Transfer units vs stages?
They are equal only when the lines are parallel (λ = 1).
Add margin?
Add for distributors and uncertainty in H_OG.