Worked example
Example: 30 m3/h, 5 min, half full, L/D 3. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Reflux + distillate liquid flow | 30.000 m³/h |
| Hold-up time (normal to empty) | 5.0000 min |
| Liquid fill at normal level (volume fraction) | 50.000 % |
| Length to diameter ratio | 3.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Liquid hold-up | 2.5000 m³ |
| Drum volume | 5.0000 m³ |
| Diameter | 1.2850 m |
| Length | 3.8551 m |
Open this example in the calculator and change any input.
Formula
\(V_L = \dot V_L t_h, \quad V = \frac{V_L}{\phi}, \quad D = \sqrt[3]{\frac{4V}{\pi(L/D)}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V_L\) | Reflux + distillate liquid flow | m³/s |
| \(t_h\) | Hold-up time (normal to empty) | s |
| \(\phi\) | Liquid fill at normal level (volume fraction) | - |
| \(L/D\) | Length to diameter ratio | - |
| \(V_L\) | Liquid hold-up | m³ |
| \(V\) | Drum volume | m³ |
| \(D\) | Diameter | m |
| \(L\) | Length | m |
Method and standards
Hold-up definition and cylinder geometry.
Where it is used
- Overhead system design.
Common mistakes
- Basing hold-up on distillate only.
- Forgetting vapour space.
Assumptions and limits
- Cylinder only; heads ignored.
- φ is the liquid volume fraction. In a horizontal drum the level and volume fractions are equal only at half full; convert a level fraction to volume with the segment geometry before entering it.
References
- Vessel volume from hold-up time (definition); typical hold-up times and L/D are design choices
Questions and answers
What hold-up time is usual?
About 5 minutes on reflux plus distillate for a level-controlled drum; more if it feeds a downstream unit.
Why only half full?
Room above the liquid lets vapour and inerts separate and the level swing.
Does it include heads?
No: the cylinder only; heads add a little volume.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.