Worked example
Example: Toluene-like points. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Point 1: temperature | 50.000 °C |
| Point 1: vapour pressure | 12.300 kPa |
| Point 2: temperature | 80.000 °C |
| Point 2: vapour pressure | 47.400 kPa |
| Point 3: temperature | 110.00 °C |
| Point 3: vapour pressure | 140.60 kPa |
| Temperature to check | 95.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| A (for log₁₀ p in mmHg, t in °C) | 7.4187 |
| B (°C, for p in mmHg) | 1,359.4 |
| C (°C) | 199.26 |
| Vapour pressure at the check temperature | 83.930 kPa |
Open this example in the calculator and change any input.
Formula
\(\log_{10} p = A - \frac{B}{C + t}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_{1}\) | Point 1: temperature | K |
| \(p_{1}\) | Point 1: vapour pressure | Pa |
| \(T_{2}\) | Point 2: temperature | K |
| \(p_{2}\) | Point 2: vapour pressure | Pa |
| \(T_{3}\) | Point 3: temperature | K |
| \(p_{3}\) | Point 3: vapour pressure | Pa |
| \(T_q\) | Temperature to check | K |
| \(A\) | A, for log₁₀ p with p in mmHg and t in °C | - |
| \(B\) | B, in °C for p in mmHg | °C |
| \(C\) | C, in °C | °C |
| \(t\) | temperature in °C (T − 273.15) | °C |
| \(p\) | vapour pressure in mmHg in the Antoine form | mmHg |
| \(p(T_q)\) | Vapour pressure at the check temperature | Pa |
Method and standards
Exact fit of the Antoine equation through three points, in the mmHg and °C form: log₁₀ p = A − B/(C + t), linearised as y t = A t + (AC − B) − C y and solved as three linear equations. Constants in other forms (bar, kPa, K, natural log) differ: convert before using them in another calculator.
Where it is used
- Fitting your own vapour pressure data.
- Solvent recovery design.
Common mistakes
- Points too close together.
- Extrapolating beyond the points.
Assumptions and limits
- Antoine form valid over the range.
- Nearly collinear points (an ill-conditioned fit) are rejected.
References
- Exact three-point solution of the Antoine equation
- linearised as y t = A t + (AC − B) − C y
Questions and answers
What do the default points describe?
A liquid boiling near 100 °C; the check at 95 °C gives about 84 kPa.
Why three points?
Antoine has three constants.
More data?
A least-squares fit over all points is better than an exact fit to three.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.