FireCADCalc

Isothermal Flash: Vapour Fraction by Rachford–Rice

Vapour fraction and liquid and vapour compositions of an isothermal flash of up to four components from the feed composition and K-values (Rachford–Rice).

Sugar mill and cogenerationRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Three componentsFour componentsAll liquid (below bubble point)

Component 1

At the flash temperature and pressure, from a K chart, Raoult (p_sat/p) or a simulator.

Component 2

At the flash temperature and pressure, from a K chart, Raoult (p_sat/p) or a simulator.

Component 3

At the flash temperature and pressure, from a K chart, Raoult (p_sat/p) or a simulator.

Component 4

At the flash temperature and pressure, from a K chart, Raoult (p_sat/p) or a simulator.

Results

Vapour fraction40.000%
Component 1: liquid mole fraction16.667%
Component 1: vapour mole fraction50.000%
Component 2: liquid mole fraction27.778%
Component 2: vapour mole fraction33.333%
Component 3: liquid mole fraction55.556%
Component 3: vapour mole fraction16.667%
Component 4: liquid mole fraction0%
Component 4: vapour mole fraction0%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Three components. The inputs, in the units selected above:

InputValue
Component 1: feed mole fraction30.000 %
Component 1: K-value y/x3.0000 -
Component 2: feed mole fraction30.000 %
Component 2: K-value y/x1.2000 -
Component 3: feed mole fraction40.000 %
Component 3: K-value y/x0.30000 -
Component 4: feed mole fraction0 %
Component 4: K-value y/x1.0000 -

Applying the formula below gives:

ResultValue
Vapour fraction40.000 %
Component 1: liquid mole fraction16.667 %
Component 1: vapour mole fraction50.000 %
Component 2: liquid mole fraction27.778 %
Component 2: vapour mole fraction33.333 %
Component 3: liquid mole fraction55.556 %
Component 3: vapour mole fraction16.667 %
Component 4: liquid mole fraction0 %
Component 4: vapour mole fraction0 %

Open this example in the calculator and change any input.

Formula

\(\sum_i \frac{z_i (K_i - 1)}{1 + \frac{V}{F}(K_i - 1)} = 0, \quad x_i = \frac{z_i}{1 + \frac{V}{F}(K_i - 1)}, \quad y_i = K_i x_i\)

Variables

Symbol Meaning SI unit
\(z_{1}\) Component 1: feed mole fraction -
\(K_{1}\) Component 1: K-value y/x -
\(z_{2}\) Component 2: feed mole fraction -
\(K_{2}\) Component 2: K-value y/x -
\(z_{3}\) Component 3: feed mole fraction -
\(K_{3}\) Component 3: K-value y/x -
\(z_{4}\) Component 4: feed mole fraction -
\(K_{4}\) Component 4: K-value y/x -
\(V/F\) Vapour fraction -
\(x_{1}\) Component 1: liquid mole fraction -
\(y_{1}\) Component 1: vapour mole fraction -
\(x_{2}\) Component 2: liquid mole fraction -
\(y_{2}\) Component 2: vapour mole fraction -
\(x_{3}\) Component 3: liquid mole fraction -
\(y_{3}\) Component 3: vapour mole fraction -
\(x_{4}\) Component 4: liquid mole fraction -
\(y_{4}\) Component 4: vapour mole fraction -

Method and standards

Rachford–Rice.

Where it is used

  • Flash drums and separators.
  • Condensate and LPG systems.

Common mistakes

  • K-values at the wrong temperature.
  • Unnormalised feed.

Assumptions and limits

  • Constant K at the flash conditions.
  • For an all-liquid or all-vapour result the other phase's fractions are incipient values (K z or z/K), not normalised; they do not add to 1.

References

  • Rachford and Rice (1952) equation Σ z_i(K_i − 1)/(1 + V(K_i − 1)) = 0

Questions and answers

30/30/40 % with K 3, 1.2 and 0.3?

About 40 % vaporises.

Where do K-values come from?

A K chart, Raoult's law (p_sat/p) for ideal mixtures, or a simulator.

Why check bubble and dew first?

Outside them the equation has no root between 0 and 1.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.