Worked example
Example: Ethanol–water x = 0.3, 80 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mole fraction of component 1 | 30.000 % |
| Temperature | 80.000 °C |
| Wilson energy a₁₂ | 399.00 cal/mol |
| Wilson energy a₂₁ | 933.00 cal/mol |
| Molar volume of component 1 | 58.680 cm³/mol |
| Molar volume of component 2 | 18.070 cm³/mol |
Applying the formula below gives:
| Result | Value |
|---|---|
| Activity coefficient of 1 | 1.6884 |
| Activity coefficient of 2 | 1.2072 |
| γ₁ at infinite dilution | 6.6001 |
| γ₂ at infinite dilution | 2.6571 |
| Excess Gibbs energy / RT | 0.28895 |
Open this example in the calculator and change any input.
Formula
\(\ln\gamma_1 = -\ln(x_1 + \Lambda_{12}x_2) + x_2\left(\frac{\Lambda_{12}}{x_1 + \Lambda_{12}x_2} - \frac{\Lambda_{21}}{x_2 + \Lambda_{21}x_1}\right)\)
\(\Lambda_{12} = \frac{V_2}{V_1}e^{-a_{12}/RT}, \quad \ln\gamma_1^\infty = -\ln\Lambda_{12} + 1 - \Lambda_{21}, \quad \frac{G^E}{RT} = -x_1\ln(x_1 + \Lambda_{12}x_2) - x_2\ln(x_2 + \Lambda_{21}x_1)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(x_1\) | Mole fraction of component 1 | - |
| \(T\) | Temperature | K |
| \(a_{12}\) | Wilson energy a₁₂ | J/mol |
| \(a_{21}\) | Wilson energy a₂₁ | J/mol |
| \(V_1\) | Molar volume of component 1 | m³/mol |
| \(V_2\) | Molar volume of component 2 | m³/mol |
| \(\gamma_1\) | Activity coefficient of 1 | - |
| \(\gamma_2\) | Activity coefficient of 2 | - |
| \(\gamma_1^\infty\) | γ₁ at infinite dilution | - |
| \(\gamma_2^\infty\) | γ₂ at infinite dilution | - |
| \(G^E/RT\) | Excess Gibbs energy / RT | - |
| \(R\) | Gas constant 8.314 462 618 | J/(mol·K) |
Method and standards
Wilson local-composition model as given in Perry's sec. 4.
Where it is used
- VLE for distillation design.
- Checking literature parameters against data.
Common mistakes
- Swapping a₁₂ and a₂₁.
- Mixing cal and J.
Assumptions and limits
- Miscible liquids only.
- The default energies are FireCAD's fit to FireCAD ethanol–water x–y–T data, not published parameters; use literature values for other systems.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 4 (thermodynamics: excess Gibbs energy models)
- Wilson equation
Questions and answers
Can Wilson predict two liquid phases?
No; for partially miscible systems use NRTL.
What units are the energies in?
J/mol here; DECHEMA tables give cal/mol, selectable in the unit list.
What do the defaults represent?
Ethanol (1)–water (2) with energies 399 and 933 cal/mol fitted by FireCAD to FireCAD ethanol–water x–y–T data at 1 atm (the same fit as the ethanol–water VLE pages).
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.