Worked example
Example: 8 % vol wash. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Liquid strength entered as | % vol at 20 °C |
| Liquid strength | 8.0000 % |
| Pressure | 101.33 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Liquid mole fraction of ethanol | 2.6025 % |
| Boiling (bubble) point | 93.518 °C |
| Vapour mole fraction of ethanol | 22.788 % |
| Strength of the condensed vapour | 50.624 % |
| Relative volatility ethanol/water | 11.046 |
| Activity coefficient of ethanol | 4.9547 |
| Activity coefficient of water | 1.0029 |
| Azeotrope mole fraction at this pressure | 88.544 % |
Open this example in the calculator and change any input.
Formula
\(y_1 P = x_1\gamma_1 p_1^s(T), \quad y_2 P = x_2\gamma_2 p_2^s(T), \quad \ln\gamma_1 = -\ln(x_1 + \Lambda_{12}x_2) + x_2\left(\frac{\Lambda_{12}}{x_1 + \Lambda_{12}x_2} - \frac{\Lambda_{21}}{x_2 + \Lambda_{21}x_1}\right)\)
\(\Lambda_{12} = \frac{V_2}{V_1}e^{-a_{12}/RT}, \quad \Lambda_{21} = \frac{V_1}{V_2}e^{-a_{21}/RT}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{basis}\) | Liquid strength entered as | - |
| \(s\) | Liquid strength | - |
| \(P\) | Pressure | Pa |
| \(x_1\) | Liquid mole fraction of ethanol | - |
| \(T_b\) | Boiling (bubble) point | K |
| \(y_1\) | Vapour mole fraction of ethanol | - |
| \(q_y\) | Strength of the condensed vapour | - |
| \(\alpha\) | Relative volatility ethanol/water | - |
| \(\gamma_1\) | Activity coefficient of ethanol | - |
| \(\gamma_2\) | Activity coefficient of water | - |
| \(x_{az}\) | Azeotrope mole fraction at this pressure | - |
| \(\gamma_1, \gamma_2\) | Activity coefficients of ethanol and water (Wilson) | - |
| \(p_1^s, p_2^s\) | Vapour pressures of ethanol and water | Pa |
| \(\Lambda_{12}, \Lambda_{21}, a_{12}, a_{21}\) | Wilson parameters (399 and 933 cal/mol; V₁ 58.68, V₂ 18.07 cm³/mol) | - |
Method and standards
Modified Raoult's law with Wilson activity coefficients; bubble temperature by bisection.
Where it is used
- Beer and rectifying column design.
- Reading tray temperatures in distilleries.
Common mistakes
- Using Raoult's law without activity coefficients.
- Mixing % vol and mole fraction.
Assumptions and limits
- Wilson energies fitted at 1 atm; 0.9–1.2 atm only.
- Binary ethanol–water; congeners and dissolved solids ignored.
References
- Ethanol–water VLE at about 1 atm: Wilson equation (Perry's Chemical Engineers' Handbook, 9th ed., sec. 4) with energies 399 and 933 cal/mol fitted to FireCAD ethanol–water x–y–T data at 101.325 kPa; ethanol vapour pressure Perry's 9th ed. Table 2-8; water IAPWS-IF97
- Checked against Gmehling and Onken
- DECHEMA Chemistry Data Series vol. I/1
- as quoted in Perry's 9th ed. sec. 13 (simple batch distillation example)
Questions and answers
Why is the vapour so much richer than the wash?
Ethanol's activity coefficient in water is about 6 at infinite dilution, so dilute wash gives vapour several times richer.
Where is the azeotrope?
About 0.89 mole fraction (95.6 % mass, about 97 % vol) at 78.1–78.2 °C; this model gives 0.885.
How accurate is the model?
Within 0.014 in y and 0.8 °C of the fitted table, and within 0.008 of DECHEMA points quoted in Perry's.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.