Beer Column with Live Steam: Stages and Minimum Steam

Stripping stages, minimum and actual live-steam ratio and top vapour strength of a beer (wash) column fed at the top with live steam at the base, McCabe–Thiele.

Distillery and ethanolIAPWS-IF97 (water and steam)

Inputs

Examples: 8 % vol beer, 0.02 % stillage, 180 kg/t12 % vol beer, 220 kg/t

% vol at 20 °C.
Model fitted at 1 atm; use 0.9–1.2 atm.

Results

Live steam dilutes the stillage; a reboiler avoids that but costs a heat exchanger. Beer solids and CO₂ are ignored.

Beer mole fraction2.6025%
Stillage mole fraction0.006184%
Minimum steam per tonne of beer109.49kg/t
Top vapour mole fraction13.862%
Top vapour strength (as condensate)35.285%
Theoretical stages6.6187
Ethanol recovered overhead99.762%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 8 % vol beer, 0.02 % stillage, 180 kg/t. The inputs, in the units selected above:

InputValue
Beer strength8.0000 %
Stillage (bottoms) strength0.020000 %
Live steam per tonne of beer180.00 kg/t
Pressure101.33 kPa

Applying the formula below gives:

ResultValue
Beer mole fraction2.6025 %
Stillage mole fraction0.006184 %
Minimum steam per tonne of beer109.49 kg/t
Top vapour mole fraction13.862 %
Top vapour strength (as condensate)35.285 %
Theoretical stages6.6187
Ethanol recovered overhead99.762 %

Open this example in the calculator and change any input.

Formula

\(y = \frac{F}{S}(x - x_B), \quad \left(\frac{S}{F}\right)_{min,molar} = \frac{x_F - x_B}{y^*(x_F)}, \quad \left(\frac{S}{F}\right)_{min} = \frac{x_F - x_B}{y^*(x_F)}\,n_F M_W\)

Variables

Symbol Meaning SI unit
\(q_F\) Beer strength -
\(q_B\) Stillage (bottoms) strength -
\(S/F\) Live steam per tonne of beer kg/kg
\(P\) Pressure Pa
\(x_F\) Beer mole fraction -
\(x_B\) Stillage mole fraction -
\((S/F)_{min}\) Minimum steam per tonne of beer kg/kg
\(y_1\) Top vapour mole fraction -
\(q_y\) Top vapour strength (as condensate) -
\(N\) Theoretical stages -
\(\eta\) Ethanol recovered overhead -
\(y^*(x_F)\) vapour in equilibrium with the beer -
\(n_F\) moles per kg of beer kmol/kg
\(M_W\) molar mass of water (steam) kg/kmol
\(F\), \(S\) beer and live steam, molar flows kmol/s

Method and standards

McCabe–Thiele for a stripping column with live steam, constant molar overflow.

Where it is used

  • Beer (analyser) column design.
  • Steam reduction studies.

Common mistakes

  • Using a reboiler operating line for live steam.
  • Forgetting that steam is per tonne of beer.

Assumptions and limits

  • Wilson energies fitted at 1 atm; 0.9–1.2 atm only.
  • Binary ethanol–water; congeners and dissolved solids ignored.
  • Beer fed as saturated liquid on the top tray; beer subcooling is not counted.
  • Constant molar overflow with live steam: the differing latent heats of ethanol and water are ignored. The minimum steam assumes the pinch is at the feed.

References

  • Ethanol–water VLE at about 1 atm: Wilson equation (Perry's Chemical Engineers' Handbook, 9th ed., sec. 4) with energies 399 and 933 cal/mol fitted to FireCAD ethanol–water x–y–T data at 101.325 kPa; ethanol vapour pressure Perry's 9th ed. Table 2-8; water IAPWS-IF97
  • Checked against Gmehling and Onken
  • DECHEMA Chemistry Data Series vol. I/1
  • as quoted in Perry's 9th ed. sec. 13 (simple batch distillation example)
  • Stripping with open steam: operating line through (x_B, 0)
  • constant molar overflow (Perry's 9th ed. sec. 13)

Questions and answers

Why is there a minimum steam?

The top vapour cannot be richer than the equilibrium with the beer; at that point the column needs infinite stages.

How rich is the top vapour?

From 8 % vol beer, about 35 % vol as condensate; richer beer gives stronger vapour.

Why does the stillage spec matter?

Each tenfold cut in stillage ethanol adds a few stages near the bottom.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.