Worked example
Example: 94 % vol from 0.1 % vol. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Distillate strength | 94.000 % |
| Bottoms strength | 0.10000 % |
| Pressure | 101.33 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Distillate mole fraction | 79.830 % |
| Bottoms mole fraction | 0.030938 % |
| Minimum stages (reboiler = 1) | 7.6104 |
Open this example in the calculator and change any input.
Formula
\(y_{n+1} = x_n, \quad x_n = x^*(y_n)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(q_D\) | Distillate strength | - |
| \(q_B\) | Bottoms strength | - |
| \(P\) | Pressure | Pa |
| \(x_D\) | Distillate mole fraction | - |
| \(x_B\) | Bottoms mole fraction | - |
| \(N_{min}\) | Minimum stages (reboiler = 1) | - |
Method and standards
Stepping between the equilibrium curve and the diagonal.
Where it is used
- Short-cut column design.
- Checking existing columns.
Common mistakes
- Using a mean α.
- Specifying a distillate above the azeotrope.
Assumptions and limits
- Wilson energies fitted at 1 atm; 0.9–1.2 atm only.
- Binary ethanol–water; congeners and dissolved solids ignored.
- Near the azeotrope (above about 94 % vol) N_min depends strongly on the accuracy of the fitted curve there; a note says so.
References
- Ethanol–water VLE at about 1 atm: Wilson equation (Perry's Chemical Engineers' Handbook, 9th ed., sec. 4) with energies 399 and 933 cal/mol fitted to FireCAD ethanol–water x–y–T data at 101.325 kPa; ethanol vapour pressure Perry's 9th ed. Table 2-8; water IAPWS-IF97
- Checked against Gmehling and Onken
- DECHEMA Chemistry Data Series vol. I/1
- as quoted in Perry's 9th ed. sec. 13 (simple batch distillation example)
- Total reflux: operating line on the diagonal (Perry's 9th ed. sec. 13, Fig. 13-25)
Questions and answers
Why not use the Fenske equation?
Ethanol–water's relative volatility falls from about 10 to 1 across the column, so a single α is meaningless.
Why does 94 % vol need so many stages?
Near the azeotrope each stage gains very little.
Is this the actual stage count?
No, it is the minimum at infinite reflux; use the McCabe–Thiele calculator for a real reflux.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.