Worked example
Example: Madson example 1: 100 gpm of 10 % beer, L/V 5. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Beer | 22.712 m³/h |
| Ethanol in the beer | 10.000 % |
| Liquid / vapour ratio at the base | 5.0000 - |
| Density used for the water in the beer | 998.55 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water in the beer | 20,412 kg/h |
| Stripping steam | 4,082.3 kg/h |
| Ethanol in the beer | 2,271.2 L/h |
| Steam per litre of ethanol | 1.7974 kg/L |
Open this example in the calculator and change any input.
Formula
\(L = Q(1 - x)\rho_w, \quad V = \frac{L}{L/V}, \quad \frac{V}{\dot V_E} = \frac{V}{Qx}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Beer | m³/s |
| \(x\) | Ethanol in the beer | - |
| \(L/V\) | Liquid / vapour ratio at the base | - |
| \(\rho_w\) | Density used for the water in the beer | kg/m³ |
| \(L\) | Water in the beer | kg/s |
| \(V\) | Stripping steam | kg/s |
| \(\dot V_E\) | Ethanol in the beer | m³/s |
| \(V/\dot V_E\) | Steam per litre of ethanol | kg/m³ |
Method and standards
Madson's simplified stripping balance.
Where it is used
- Distillation steam estimates.
- Valuing stronger beer.
Common mistakes
- Using mass % for volume %.
- Ignoring the heat to bring the beer to its boiling point.
Assumptions and limits
- Beer fed at its boiling point; constant molal overflow. The heat to preheat the beer to its boiling point is not included: add it if the beer is fed cold.
References
- Jacques
- Lyons and Kelsall (eds.)
- The Alcohol Textbook
- 4th ed. (Nottingham University Press, 2003)
- ch. 22 (Madson)
- ethanol distillation: the fundamentals
- Table 1
Questions and answers
Why does weak beer cost more steam?
The column must boil up enough vapour to strip every kilogram of water; weaker beer means more water per litre of ethanol.
What is L/V?
The molar liquid-to-vapour ratio at the column base, where the liquid is nearly all water and the vapour nearly all steam.
Why 500 lb/h per gpm?
Madson's rounding of water at 8.33 lb/gal × 60 min.