Worked example
Example: 30 % vol feed at 90 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Feed strength entered as | % vol at 20 °C |
| Feed strength | 30.000 % |
| Flash temperature | 90.000 °C |
| Pressure | 101.33 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Feed mole fraction | 11.318 % |
| Liquid mole fraction | 5.1689 % |
| Vapour mole fraction | 33.637 % |
| Vapour fraction (molar) | 21.602 % |
| Liquid strength | 15.172 % |
| Condensed vapour strength | 64.318 % |
Open this example in the calculator and change any input.
Formula
\(T_b(x_1) = T, \quad y_1 = y^*(x_1), \quad \frac{V}{F} = \frac{z_1 - x_1}{y_1 - x_1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{basis}\) | Feed strength entered as | - |
| \(s_F\) | Feed strength | - |
| \(T\) | Flash temperature | K |
| \(P\) | Pressure | Pa |
| \(z_1\) | Feed mole fraction | - |
| \(x_1\) | Liquid mole fraction | - |
| \(y_1\) | Vapour mole fraction | - |
| \(V/F\) | Vapour fraction (molar) | - |
| \(q_x\) | Liquid strength | - |
| \(q_y\) | Condensed vapour strength | - |
Method and standards
Equilibrium at the flash temperature with the lever rule.
Where it is used
- Flash drums and single-stage stills.
- Teaching T–x–y diagrams.
Common mistakes
- Treating a mass fraction as molar.
- Flashing above the dew point.
Assumptions and limits
- Wilson energies fitted at 1 atm; 0.9–1.2 atm only.
- Binary ethanol–water; congeners and dissolved solids ignored.
References
- Ethanol–water VLE at about 1 atm: Wilson equation (Perry's Chemical Engineers' Handbook, 9th ed., sec. 4) with energies 399 and 933 cal/mol fitted to FireCAD ethanol–water x–y–T data at 101.325 kPa; ethanol vapour pressure Perry's 9th ed. Table 2-8; water IAPWS-IF97
- Checked against Gmehling and Onken
- DECHEMA Chemistry Data Series vol. I/1
- as quoted in Perry's 9th ed. sec. 13 (simple batch distillation example)
Questions and answers
How is the split found?
At the flash temperature the liquid and vapour lie on the bubble and dew curves; the lever rule gives the vapour fraction.
Why must the temperature be between bubble and dew points?
Outside that band the feed is wholly liquid or wholly vapour.
Is the vapour fraction molar?
Yes; convert with molar masses for kilograms.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.