Worked example
Example: Still at 87 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Measured boiling temperature | 87.000 °C |
| Pressure | 101.33 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Liquid mole fraction | 8.9996 % |
| Liquid strength | 24.766 % |
| Liquid strength by mass | 20.185 % |
| Vapour mole fraction | 42.249 % |
| Condensed vapour strength | 72.582 % |
Open this example in the calculator and change any input.
Formula
\(T_b(x_1, P) = T_{\text{measured}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T\) | Measured boiling temperature | K |
| \(P\) | Pressure | Pa |
| \(x_1\) | Liquid mole fraction | - |
| \(q_x\) | Liquid strength | - |
| \(p_x\) | Liquid strength by mass | - |
| \(y_1\) | Vapour mole fraction | - |
| \(q_y\) | Condensed vapour strength | - |
Method and standards
Inverse of the bubble-point curve by bisection.
Where it is used
- Column temperature control.
- Pot still cut points.
Common mistakes
- Ignoring barometric pressure.
- Using it near the azeotrope.
Assumptions and limits
- Wilson energies fitted at 1 atm; 0.9–1.2 atm only.
- Binary ethanol–water; congeners and dissolved solids ignored.
- Near the azeotrope the bubble curve is so flat that an error of a few tenths of a degree, in the reading or in the fitted model, moves the strength a long way; no uncertainty is computed, so read strong liquids by density.
References
- Ethanol–water VLE at about 1 atm: Wilson equation (Perry's Chemical Engineers' Handbook, 9th ed., sec. 4) with energies 399 and 933 cal/mol fitted to FireCAD ethanol–water x–y–T data at 101.325 kPa; ethanol vapour pressure Perry's 9th ed. Table 2-8; water IAPWS-IF97
- Checked against Gmehling and Onken
- DECHEMA Chemistry Data Series vol. I/1
- as quoted in Perry's 9th ed. sec. 13 (simple batch distillation example)
Questions and answers
Can a pot still thermometer tell the strength?
Roughly: at 1 atm a liquid boiling at 90 °C holds about 12 % mass ethanol, at 85 °C about 29 %.
Why is it poor near the top?
Between 50 % and 90 % mole the boiling point spans only about 1.7 °C.
Does pressure matter?
Yes; a 1 kPa change shifts the boiling point by about 0.3 °C: enter the actual pressure.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.