Worked example
Example: 95 % vol from 45 % vol vapour, 100 m3/day. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Product strength | 95.000 % |
| Feed (vapour) strength, as condensate | 45.000 % |
| Feed condition (0 saturated vapour) | 0 - |
| Reflux multiple | 1.3000 - |
| Product at 20 °C | 4.1667 m³/h |
| Pressure | 101.33 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Minimum reflux ratio | 3.6928 |
| Design reflux ratio | 4.8006 |
| Distillate | 82.061 kmol/h |
| Vapour to the condenser | 476.01 kmol/h |
| Vapour mass flow | 19,611 kg/h |
| Reflux | 393.94 kmol/h |
Open this example in the calculator and change any input.
Formula
\(\frac{R_{min}}{R_{min}+1} = \max\frac{x_D - y^*(x)}{x_D - x}, \quad V = (R + 1)D, \quad L = RD\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(q_D\) | Product strength | - |
| \(q_F\) | Feed (vapour) strength, as condensate | - |
| \(q\) | Feed condition (0 saturated vapour) | - |
| \(R/R_{min}\) | Reflux multiple | - |
| \(\dot V_P\) | Product at 20 °C | m³/s |
| \(P\) | Pressure | Pa |
| \(R_{min}\) | Minimum reflux ratio | - |
| \(R\) | Design reflux ratio | - |
| \(D\) | Distillate | mol/s |
| \(V\) | Vapour to the condenser | mol/s |
| \(\dot m_V\) | Vapour mass flow | kg/s |
| \(L\) | Reflux | mol/s |
Method and standards
Tangent-pinch minimum reflux with the fitted Wilson equilibrium; distillate moles from the product's R 22 density.
Where it is used
- Rectifier sizing and steam budgets.
Common mistakes
- Taking Rmin at the feed pinch.
- Forgetting that D is molar.
Assumptions and limits
- Wilson energies fitted at 1 atm; 0.9–1.2 atm only.
- Binary ethanol–water; congeners and dissolved solids ignored.
- Above about 94 % vol the product is close to the model azeotrope; small errors in the fitted equilibrium curve then change R_min a lot, and a note says so.
References
- Ethanol–water VLE at about 1 atm: Wilson equation (Perry's Chemical Engineers' Handbook, 9th ed., sec. 4) with energies 399 and 933 cal/mol fitted to FireCAD ethanol–water x–y–T data at 101.325 kPa; ethanol vapour pressure Perry's 9th ed. Table 2-8; water IAPWS-IF97
- Checked against Gmehling and Onken
- DECHEMA Chemistry Data Series vol. I/1
- as quoted in Perry's 9th ed. sec. 13 (simple batch distillation example)
- Minimum reflux by the tangent to the equilibrium curve (Perry's 9th ed. sec. 13, McCabe–Thiele limiting cases)
Questions and answers
Why does the reflux rise steeply above 94 % vol?
The equilibrium curve approaches the diagonal near the azeotrope, so the tangent pinch needs ever more reflux.
Why feed as vapour?
Rectifiers are usually fed with vapour from the beer column (q = 0).
How do I get the condenser duty?
Multiply the vapour mass flow by the latent heat of the top vapour, or use the rectifier condenser calculator.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.