Worked example
Example: 95 % / 5 %, feed 50 %, alpha 2.5. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Light key in the distillate (mole fraction) | 95.000 % |
| Light key in the bottoms | 5.0000 % |
| Light key in the feed (saturated liquid) | 50.000 % |
| Relative volatility (mean) | 2.5000 - |
| Operating reflux as a multiple of the minimum | 1.3000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Minimum theoretical stages (including the reboiler) | 6.4269 |
| Vapour in equilibrium with the feed | 71.429 % |
| Minimum reflux ratio | 1.1000 |
| Operating reflux ratio | 1.4300 |
Open this example in the calculator and change any input.
Formula
\(N_{min} = \frac{\ln\left[\frac{x_D}{1 - x_D} \cdot \frac{1 - x_B}{x_B}\right]}{\ln \alpha}\)
\(y_F^* = \frac{\alpha x_F}{1 + (\alpha - 1) x_F}, \quad R_{min} = \frac{x_D - y_F^*}{y_F^* - x_F}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(x_D\) | Light key in the distillate (mole fraction) | - |
| \(x_B\) | Light key in the bottoms | - |
| \(x_F\) | Light key in the feed (saturated liquid) | - |
| \(\alpha\) | Relative volatility (mean) | - |
| \(R/R_{min}\) | Operating reflux as a multiple of the minimum | - |
| \(N_{min}\) | Minimum theoretical stages (including the reboiler) | - |
| \(y_F^*\) | Vapour in equilibrium with the feed | - |
| \(R_{min}\) | Minimum reflux ratio | - |
| \(R\) | Operating reflux ratio | - |
Method and standards
Fenske's equation at total reflux with a constant relative volatility; the minimum reflux comes from the pinch where the rectifying line meets the equilibrium curve at the feed composition.
Where it is used
- Shortcut design of solvent recovery and stripping columns.
- Checking whether an existing column can make a sharper cut.
- Teaching.
Common mistakes
- Using a relative volatility far from the column average.
- Applying the binary pinch to azeotropes.
- Forgetting the reboiler counts as a stage.
Assumptions and limits
- Constant α, constant molar overflow, saturated liquid feed (q = 1); there is no feed-condition input. For other feeds use the q-line and minimum reflux calculators.
References
- M.R. Fenske (1932)
- Ind. Eng. Chem. 24
- Minimum reflux at the feed pinch (McCabe–Thiele, binary, saturated liquid feed)
Questions and answers
How many stages to split 95/5 with α 2.5?
At total reflux 6.4 theoretical stages, including the reboiler.
What is the minimum reflux?
For a 50 % saturated liquid feed, 1.10: the vapour in equilibrium with the feed is 71.4 %, and the operating line just touches it.
What reflux is used in practice?
About 1.1 to 1.5 times the minimum; this page multiplies by your choice.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.