Worked example
Example: 35 % to 8 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wet feed rate | 2,000.0 kg/h |
| Inlet moisture (wet basis) | 35.000 % |
| Outlet moisture (wet basis) | 8.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Dry solids | 1,300.0 kg/h |
| Dried product | 1,413.0 kg/h |
| Water evaporated | 586.96 kg/h |
| Inlet moisture (dry basis) | 0.53846 |
| Outlet moisture (dry basis) | 0.086957 |
Open this example in the calculator and change any input.
Formula
\(\dot m_s = \dot m_F(1 - M_1), \quad \dot m_P = \frac{\dot m_s}{1 - M_2}, \quad \dot m_w = \dot m_F - \dot m_P, \quad X = \frac{M}{1 - M}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_F\) | Wet feed rate | kg/s |
| \(M_1\) | Inlet moisture (wet basis) | - |
| \(M_2\) | Outlet moisture (wet basis) | - |
| \(\dot m_s\) | Dry solids | kg/s |
| \(\dot m_P\) | Dried product | kg/s |
| \(\dot m_w\) | Water evaporated | kg/s |
| \(X_1\) | Inlet moisture (dry basis) | - |
| \(X_2\) | Outlet moisture (dry basis) | - |
Method and standards
Dry-solids balance.
Where it is used
- Dryer sizing for bagasse, coal, sludge and chemicals.
- Heat duty estimates.
Common mistakes
- Subtracting percentages.
- Mixing wet and dry bases.
Assumptions and limits
- No solids loss.
References
- Dry-solids balance; X = M/(1 − M)
Questions and answers
2000 kg/h at 35 % dried to 8 %?
587 kg/h of water to evaporate.
Why not 35 − 8 = 27 %?
The percentages are of different total masses.
Dry basis?
Water per kg of dry solid: 0.54 in and 0.087 out here.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.