Worked example
Example: K 3, S/F 1, three stages. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Distribution coefficient (extract/raffinate, same basis) | 3.0000 - |
| Total solvent-to-feed ratio | 1.0000 - |
| Number of cross-current stages | 3.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Extraction factor, single stage | 3.0000 |
| Fraction left after one stage (all solvent) | 25.000 % |
| Fraction left after n cross-current stages | 12.500 % |
| Recovery with n stages | 87.500 % |
Open this example in the calculator and change any input.
Formula
\(E = K_D\frac{S}{F}, \quad r_1 = \frac{1}{1 + E}, \quad r_n = \left(1 + \frac{E}{n}\right)^{-n}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(K_D\) | Distribution coefficient (extract/raffinate, same basis) | - |
| \(S/F\) | Total solvent-to-feed ratio | - |
| \(n\) | Number of cross-current stages | - |
| \(E\) | Extraction factor, single stage | - |
| \(r_1\) | Fraction left after one stage (all solvent) | - |
| \(r_n\) | Fraction left after n cross-current stages | - |
| \(1 - r_n\) | Recovery with n stages | - |
Method and standards
Stage balances.
Where it is used
- Laboratory and batch extractions.
- Comparing cross-current with counter-current schemes.
Common mistakes
- Using K_D on a different concentration basis.
- Ignoring solvent solubility in the feed.
Assumptions and limits
- Immiscible phases; equilibrium stages.
- The total solvent is divided equally among the n stages (S/n each), which is what the form (1 + E/n)^−n assumes; unequal splits extract less.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 15 (extraction factor; cross-current extraction)
Questions and answers
Why split the solvent?
Several small contacts extract more than one large one: with E = 3, one stage leaves 25 %, three stages of one-third each leave 12.5 %.
What is the extraction factor?
K_D·S/F: how much of the solute the solvent can carry compared with the feed.
What do the defaults represent?
A solute with K_D 3 extracted with an equal mass of solvent in one stage or split over three.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.