FireCADCalc

Latent Heat at Another Temperature (Watson Correlation)

Heat of vaporisation at a second temperature from a known value and the critical temperature by the Watson correlation (exponent 0.38).

Sugar mill and cogenerationRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Water 100 to 180 °CEthanol 78 to 120 °C

Results

Latent heat at T₂1,979.4kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Water 100 to 180 °C. The inputs, in the units selected above:

InputValue
Known latent heat2,257.0 kJ/kg
Temperature of the known value100.00 °C
Temperature wanted180.00 °C
Critical temperature373.95 °C

Applying the formula below gives:

ResultValue
Latent heat at T₂1,979.4 kJ/kg

Open this example in the calculator and change any input.

Formula

\(\Delta H_2 = \Delta H_1\left(\frac{1 - T_2/T_c}{1 - T_1/T_c}\right)^{0.38}\)

Variables

Symbol Meaning SI unit
\(\Delta H_1\) Known latent heat J/kg
\(T_1\) Temperature of the known value K
\(T_2\) Temperature wanted K
\(T_c\) Critical temperature K
\(\Delta H_2\) Latent heat at T₂ J/kg

Method and standards

Watson.

Where it is used

  • Reboiler and condenser duties for organics.
  • Evaporator design.

Common mistakes

  • °C in the ratio.
  • Extrapolating near T_c.

Assumptions and limits

  • Below the critical temperature.

References

  • Watson (1943)
  • Ind. Eng. Chem. 35(4): ΔH₂ = ΔH₁[(1 − T_r2)/(1 − T_r1)]^0.38 (Reid, Prausnitz and Poling)

Questions and answers

Water at 180 °C from 2257 kJ/kg at 100 °C?

About 1979 kJ/kg (steam tables: about 2015).

Why 0.38?

Watson's empirical fit over many liquids.

Near the critical point?

Latent heat falls to zero there; the fit is weakest close to it.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.