Worked example
Example: Water 100 to 180 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Known latent heat | 2,257.0 kJ/kg |
| Temperature of the known value | 100.00 °C |
| Temperature wanted | 180.00 °C |
| Critical temperature | 373.95 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Latent heat at T₂ | 1,979.4 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(\Delta H_2 = \Delta H_1\left(\frac{1 - T_2/T_c}{1 - T_1/T_c}\right)^{0.38}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\Delta H_1\) | Known latent heat | J/kg |
| \(T_1\) | Temperature of the known value | K |
| \(T_2\) | Temperature wanted | K |
| \(T_c\) | Critical temperature | K |
| \(\Delta H_2\) | Latent heat at T₂ | J/kg |
Method and standards
Watson.
Where it is used
- Reboiler and condenser duties for organics.
- Evaporator design.
Common mistakes
- °C in the ratio.
- Extrapolating near T_c.
Assumptions and limits
- Below the critical temperature.
References
- Watson (1943)
- Ind. Eng. Chem. 35(4): ΔH₂ = ΔH₁[(1 − T_r2)/(1 − T_r1)]^0.38 (Reid, Prausnitz and Poling)
Questions and answers
Water at 180 °C from 2257 kJ/kg at 100 °C?
About 1979 kJ/kg (steam tables: about 2015).
Why 0.38?
Watson's empirical fit over many liquids.
Near the critical point?
Latent heat falls to zero there; the fit is weakest close to it.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.