Worked example
Example: Illustrative binary at 1 atm: x 0.40, y 0.62, 12 K boiling range, 30 kW/m2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Liquid mole fraction of the lighter component | 40.000 % |
| Vapour mole fraction of the lighter component | 62.000 % |
| Boiling point of the lighter component at the pressure | 68.750 °C |
| Boiling point of the heavier component at the pressure | 110.65 °C |
| Pure-component coefficient, lighter | 4,500.0 W/(m²·K) |
| Pure-component coefficient, heavier | 3,800.0 W/(m²·K) |
| Heat flux | 30.000 kW/m² |
| Liquid molar density | 8.0000 kmol/m³ |
| Latent heat of the mixture | 31.000 kJ/mol |
| Boiling range T_dew − T_bubble | 12.000 K |
| Pressure | 101.33 kPa |
| Critical pressure, lighter | 3,030.0 kPa |
| Critical pressure, heavier | 2,740.0 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Ideal mixture coefficient (x_i/h_i)⁻¹ | 4,052.1 W/(m²·K) |
| Schlünder | 2,589.1 W/(m²·K) |
| Thome–Shakir | 2,634.9 W/(m²·K) |
| Pseudo-reduced pressure | 0.035478 |
| Pressure factor (Palen) | 0.86512 |
| Mixture factor (Palen) | 0.58958 |
| Mostinski with Palen's mixture factor | 701.80 W/(m²·K) |
Open this example in the calculator and change any input.
Formula
\(h_{nb} = h_{ideal}\left\{1 + \frac{h_{ideal}}{\hat q}\left[1 - \exp\left(\frac{-\hat q}{\rho_L\lambda\beta}\right)\right](T_{sat,2} - T_{sat,1})(y_1 - x_1)\right\}^{-1}\)
\(h_{TS} = h_{ideal}\left\{1 + \frac{BR\,h_{ideal}}{\hat q}\left[1 - \exp\left(\frac{-\hat q}{\rho_L\lambda\beta}\right)\right]\right\}^{-1}, \quad F_m = \left(1 + 0.023\hat q^{0.15}BR^{0.75}\right)^{-1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(x_1\) | Liquid mole fraction of the lighter component | - |
| \(y_1\) | Vapour mole fraction of the lighter component | - |
| \(T_{sat,1}\) | Boiling point of the lighter component at the pressure | K |
| \(T_{sat,2}\) | Boiling point of the heavier component at the pressure | K |
| \(h_{nb,1}\) | Pure-component coefficient, lighter | W/(m²·K) |
| \(h_{nb,2}\) | Pure-component coefficient, heavier | W/(m²·K) |
| \(\hat q\) | Heat flux | W/m² |
| \(\rho_L\) | Liquid molar density | mol/m³ |
| \(\lambda\) | Latent heat of the mixture | J/mol |
| \(BR\) | Boiling range T_dew − T_bubble | K |
| \(P\) | Pressure | Pa |
| \(P_{c,1}\) | Critical pressure, lighter | Pa |
| \(P_{c,2}\) | Critical pressure, heavier | Pa |
| \(h_{ideal}\) | Ideal mixture coefficient (x_i/h_i)⁻¹ | W/(m²·K) |
| \(h_{Schl}\) | Schlünder | W/(m²·K) |
| \(h_{TS}\) | Thome–Shakir | W/(m²·K) |
| \(P_{pr}\) | Pseudo-reduced pressure | - |
| \(F_P\) | Pressure factor (Palen) | - |
| \(F_m\) | Mixture factor (Palen) | - |
| \(h_{Palen}\) | Mostinski with Palen's mixture factor | W/(m²·K) |
Method and standards
Mixture corrections to nucleate pool boiling coefficients.
Where it is used
- Reboilers on multicomponent columns.
- Vaporisers for wide-boiling hydrocarbon mixtures.
Common mistakes
- Using the mole-average of pure coefficients without the mixture correction.
- Applying Palen's factor to correlations other than Mostinski.
Assumptions and limits
- Binary mixtures (Schlünder); pool boiling.
References
- Schlünder and Thome–Shakir mixture corrections to the ideal coefficient; Palen's Mostinski factor
Questions and answers
Why do mixtures boil worse than pure liquids?
The lighter component evaporates preferentially, leaving the liquid at the wall richer in the heavier one; its higher boiling point and the extra mass transfer resistance reduce the coefficient, often below either pure value.
Which method should I use?
Schlünder when the vapour–liquid equilibrium is known; Thome–Shakir for petroleum cuts with a known boiling range; Palen–Mostinski for a conservative design.
What do the defaults represent?
An illustrative binary of 40 % light component boiling at 1 atm with a 12 K boiling range, pure coefficients 4,500 and 3,800 W/(m²·K) and a heat flux of 30 kW/m².
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Serth, Process Heat Transfer: Principles and Applications (Academic Press, 2007), sec. 9.3.2, eqs. 9.14 to 9.18 and Example 9.2