Worked example
Example: Illustrative: pipe at 300 C (eps 0.8) in a jacket at 50 C (eps 0.3), r1/r2 0.6. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Geometry | Long concentric cylinders |
| Area of the inner (or first) surface | 1.0000 m² |
| Radius ratio (cylinders, spheres) or area ratio (general) | 0.60000 - |
| View factor from 1 to 2 (general only) | 1.0000 - |
| Emissivity of surface 1 | 80.000 % |
| Emissivity of surface 2 | 30.000 % |
| Temperature of surface 1 | 300.00 °C |
| Temperature of surface 2 | 50.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Net radiation from 1 to 2 | 2.0757 kW |
| Net flux on surface 1 | 2,075.7 W/m² |
| Effective emissivity q/(σA₁(T₁⁴ − T₂⁴)) | 0.37736 |
| Area ratio used | 0.60000 |
| Radiosity of surface 1 | 5,600.1 W/m² |
| Radiosity of surface 2 | 3,524.4 W/m² |
Open this example in the calculator and change any input.
Formula
\(q_{12} = \frac{\sigma A_1(T_1^4 - T_2^4)}{\frac{1 - \varepsilon_1}{\varepsilon_1} + \frac{1}{F_{12}} + \frac{1 - \varepsilon_2}{\varepsilon_2}\frac{A_1}{A_2}}, \quad \frac{A_1}{A_2} = \frac{r_1}{r_2}\ \text{(cylinders)}, \ \left(\frac{r_1}{r_2}\right)^2\ \text{(spheres)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{geometry}\) | Geometry | - |
| \(A_1\) | Area of the inner (or first) surface | m² |
| \(r_1/r_2\ \text{or}\ A_1/A_2\) | Radius ratio (cylinders, spheres) or area ratio (general) | - |
| \(F_{12}\) | View factor from 1 to 2 (general only) | - |
| \(\varepsilon_1\) | Emissivity of surface 1 | - |
| \(\varepsilon_2\) | Emissivity of surface 2 | - |
| \(T_1\) | Temperature of surface 1 | K |
| \(T_2\) | Temperature of surface 2 | K |
| \(q_{12}\) | Net radiation from 1 to 2 | W |
| \(q_{12}/A_1\) | Net flux on surface 1 | W/m² |
| \(\varepsilon_{eff}\) | Effective emissivity q/(σA₁(T₁⁴ − T₂⁴)) | - |
| \(A_1/A_2\) | Area ratio used | - |
| \(J_1\) | Radiosity of surface 1 | W/m² |
| \(J_2\) | Radiosity of surface 2 | W/m² |
Method and standards
Radiosity network for a two-surface gray enclosure.
Where it is used
- Jacketed and insulated pipes, double-walled vessels and cryostats.
- Thermocouple wells and furnace tubes.
Common mistakes
- Using the parallel-plate formula for cylinders.
- Forgetting that the inner surface must be convex (F₁₁ = 0).
Assumptions and limits
- Diffuse gray surfaces, uniform temperatures and radiosities, non-participating gas.
References
- Two-surface radiosity network for diffuse gray surfaces
Questions and answers
Why does the outer surface emissivity matter less for a small inner body?
Its resistance is scaled by A₁/A₂; when the outer surface is much larger it behaves almost like a black cavity.
Can I use it for a pipe inside a jacket?
Yes: choose concentric cylinders, enter the pipe's area per metre and the radius ratio of pipe to jacket.
What do the defaults represent?
An illustrative pipe at 300 °C (ε 0.8) inside a jacket at 50 °C (ε 0.3) with a radius ratio of 0.6, per square metre of pipe surface.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Incropera, DeWitt, Bergman and Lavine, Fundamentals of Heat and Mass Transfer, 6th ed. (Wiley, 2007), sec. 13.3, Table 13.3