FireCADCalc

Nucleate Pool Boiling by Forster–Zuber with Zuber Critical Flux

Nucleate pool boiling coefficient and heat flux of any liquid by Forster–Zuber from fluid properties and wall superheat, checked against Zuber's critical flux.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Water at 1 atm, wall 110 C (IAPWS properties)Benzene at 1 atm (80.1 C), wall 95 C

Accepted: 0.01 to 2 W/(m·K)
Accepted: 0.5 to 8 kJ/(kg·K)
Accepted: 100 to 2,000 kg/m³
Accepted: 0.01 to 500 kg/m³
Accepted: 0.1 to 100 mN/m
Accepted: 0.001 to 10 mPa·s
Accepted: 10 to 4,000 kJ/kg
Accepted: -123.15 to 526.85 °C
Accepted: -123.15 to 526.85 °C
Accepted: 0.001 to 300 bar
Accepted: 0.001 to 300 bar

Results

Forster and Zuber (1955) in SI units; the saturation pressure at the wall temperature comes from steam tables (or the fluid's vapour-pressure curve). Pool boiling coefficients depend on the surface; treat the result as an estimate within about ±50 %.

Nucleate boiling coefficient8,436.0W/(m²·K)
Heat flux84.613kW/m²
Zuber critical heat flux1,108.9kW/m²
Share of the critical flux7.6306%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Water at 1 atm, wall 110 C (IAPWS properties). The inputs, in the units selected above:

InputValue
Liquid conductivity0.67900 W/(m·K)
Liquid specific heat4.2160 kJ/(kg·K)
Liquid density958.40 kg/m³
Vapour density0.59800 kg/m³
Surface tension58.900 mN/m
Liquid viscosity0.28200 mPa·s
Latent heat2,257.0 kJ/kg
Wall temperature110.00 °C
Saturation temperature99.970 °C
Saturation pressure at the wall temperature1.4327 bar
System pressure1.0132 bar

Applying the formula below gives:

ResultValue
Nucleate boiling coefficient8,436.0 W/(m²·K)
Heat flux84.613 kW/m²
Zuber critical heat flux1,108.9 kW/m²
Share of the critical flux7.6306 %

Open this example in the calculator and change any input.

Formula

\(h_{nb} = 0.00122\left[\frac{k_L^{0.79}c_{pL}^{0.45}\rho_L^{0.49}}{\sigma^{0.5}\mu_L^{0.29}\lambda^{0.24}\rho_v^{0.24}}\right](T_w - T_s)^{0.24}(p_w - p_s)^{0.75}\)

\(q_c = 0.131\lambda[\sigma g(\rho_L - \rho_v)\rho_v^2]^{1/4}\)

Variables

Symbol Meaning SI unit
\(k_L\) Liquid conductivity W/(m·K)
\(c_{pL}\) Liquid specific heat J/(kg·K)
\(\rho_L\) Liquid density kg/m³
\(\rho_v\) Vapour density kg/m³
\(\sigma\) Surface tension N/m
\(\mu_L\) Liquid viscosity Pa·s
\(\lambda\) Latent heat J/kg
\(T_w\) Wall temperature K
\(T_s\) Saturation temperature K
\(p_w\) Saturation pressure at the wall temperature Pa
\(p_s\) System pressure Pa
\(h_{nb}\) Nucleate boiling coefficient W/(m²·K)
\(q\) Heat flux W/m²
\(q_c\) Zuber critical heat flux W/m²
\(q/q_c\) Share of the critical flux -

Method and standards

Forster–Zuber nucleate boiling and Zuber hydrodynamic CHF.

Where it is used

  • Reboiler and vaporiser design for organic fluids.
  • Checking boiling duties against CHF.

Common mistakes

  • Using the system pressure for p_w.
  • Applying pool-boiling values to flow boiling.

Assumptions and limits

  • Clean surfaces, pure liquids, nucleate regime.

Questions and answers

Why does it need p_w − p_s?

Forster and Zuber express the superheat partly through the vapour-pressure difference that drives bubble growth, which makes the correlation fit different fluids.

How close to CHF may I operate?

Reboilers are usually designed well below the critical flux, often at half of it or less.

What do the defaults represent?

An illustrative case: Water at 1 atm, wall 110 C (IAPWS properties). Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Sinnott, Coulson and Richardson's Chemical Engineering Vol. 6: Chemical Engineering Design, 4th ed. (Elsevier, 2005), sec. 12.11.2, eqs. 12.62 and 12.65 and Example 12.8 (Forster and Zuber, 1955; Zuber, 1958)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.