FireCADCalc

Volatile Solids Reduction in a Digester (Van Kleeck)

Volatile solids destruction from the volatile fractions of feed and digested sludge (Van Kleeck), total solids reduction and digested solids from the feed solids.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Primary plus WAS, 75 % to 58 %Weak digestion 70 % to 62 %

Accepted: 5 to 99 %
Accepted: 1 to 99 %
Accepted: 0 to 86,400,000 kg/d

Results

Van Kleeck assumes the fixed (ash) solids pass through unchanged, with no grit build-up or supernatant withdrawal. Class B biosolids need at least 38 % volatile solids reduction.

Volatile solids reduction53.968%
Total solids reduction40.476%
Digested dry solids7,142.9kg/d
Volatile solids destroyed4,857.1kg/d

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Primary plus WAS, 75 % to 58 %. The inputs, in the units selected above:

InputValue
Volatile fraction of feed solids75.000 %
Volatile fraction of digested solids58.000 %
Feed dry solids12,000 kg/d

Applying the formula below gives:

ResultValue
Volatile solids reduction53.968 %
Total solids reduction40.476 %
Digested dry solids7,142.9 kg/d
Volatile solids destroyed4,857.1 kg/d

Open this example in the calculator and change any input.

Formula

\(R_{VSS} = \frac{W_{VS,f} - W_{VS,d}}{W_{VS,f} - W_{VS,f}W_{VS,d}}, \quad M_d = M_f\frac{1 - W_{VS,f}}{1 - W_{VS,d}}\)

Variables

Symbol Meaning SI unit
\(W_{VS,f}\) Volatile fraction of feed solids -
\(W_{VS,d}\) Volatile fraction of digested solids -
\(M_f\) Feed dry solids kg/s
\(R_{VSS}\) Volatile solids reduction -
\(R_{TSS}\) Total solids reduction -
\(M_d\) Digested dry solids kg/s
\(VS_{destroyed}\) Volatile solids destroyed kg/s

Method and standards

Van Kleeck volatile solids reduction.

Where it is used

  • Digester performance and biosolids classification.
  • Gas production estimates.

Common mistakes

  • Subtracting volatile percentages directly.
  • Using it with supernatant decant.

Assumptions and limits

  • Fixed solids conserved.

Questions and answers

Why can't I just compare volatile percentages?

The total solids also fall, so 68 % to 50 % volatile is not an 18-point loss; per kilogram of feed it is 0.68 to 0.32 kg, a 53 % reduction.

When is Van Kleeck unreliable?

When grit accumulates, supernatant is withdrawn or fixed solids are added (for example lime or ferric), because the fixed solids are then not conserved.

What do the defaults represent?

An illustrative case: Primary plus WAS, 75 % to 58 %. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 13-9, eqs. 13-15 and 13-16 and Example 13-6

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.