Time for a Basin to Reaerate by Surface Transfer

Time for dissolved oxygen in a stored or slowly mixed basin to rise from an initial to a target value by surface reaeration, from K_L, area and depth.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Shallow lagoon 1.5 m, 0 to 6 mg/LDeep tank 6 m, 2 to 5 mg/L

Accepted: 1 to 20 mg/L
Accepted: 0 to 20 mg/L
Accepted: 0 to 20 mg/L
Accepted: 0.00036 to 3.6 m/h
Accepted: 0.1 to 10,000,000 m²
Accepted: 0.1 to 50 m

Results

The basin is assumed mixed so the bulk is uniform; a stagnant basin reaerates far more slowly by molecular diffusion. Shallow basins with large surfaces reaerate fastest.

Interfacial area per volume0.166671/m
Overall coefficient0.0083331/h
Time required2.7507d

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Shallow lagoon 1.5 m, 0 to 6 mg/L. The inputs, in the units selected above:

InputValue
Saturation dissolved oxygen8.2600 mg/L
Initial dissolved oxygen0 mg/L
Target dissolved oxygen6.0000 mg/L
Liquid film coefficient0.020000 m/h
Surface area20,000 m²
Depth1.5000 m

Applying the formula below gives:

ResultValue
Interfacial area per volume0.66667 1/m
Overall coefficient0.013333 1/h
Time required4.0502 d

Open this example in the calculator and change any input.

Formula

\(\frac{C_s - C_t}{C_s - C_o} = e^{-K_Lat}, \quad a = \frac{A}{V} = \frac{1}{h}\)

Variables

Symbol Meaning SI unit
\(C_s\) Saturation dissolved oxygen kg/m³
\(C_o\) Initial dissolved oxygen kg/m³
\(C_t\) Target dissolved oxygen kg/m³
\(K_L\) Liquid film coefficient m/s
\(A\) Surface area m²
\(h\) Depth m
\(a\) Interfacial area per volume 1/m
\(K_La\) Overall coefficient 1/s
\(t\) Time required s

Method and standards

First-order gas absorption.

Where it is used

  • Storage basins and lagoons for reuse water.
  • Estimating natural reaeration.

Common mistakes

  • Using the volume instead of the area in a.
  • Taking K_L for a stagnant surface.

Assumptions and limits

  • Uniform mixing; constant temperature.

Questions and answers

Is the surface area the same as A in K_La?

Here the specific area a is the surface area divided by the volume, which for a basin of uniform depth is 1/h.

What K_L should I use?

For gently mixed open basins about 0.01-0.05 m/h; Designers use 0.03 m/h for oxygen.

What do the defaults represent?

An illustrative case: Shallow lagoon 1.5 m, 0 to 6 mg/L. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 5-10, eq. 5-63 and Example 5-12

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.