Worked example
Example: 2 to 6 mg/L in 40 s, coalescing. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Saturation dissolved oxygen | 7.5000 mg/L |
| Dissolved oxygen at t₁ | 2.0000 mg/L |
| Dissolved oxygen at t₂ | 6.0000 mg/L |
| Time between the readings | 40.000 s |
| Gassed power per volume | 1.0000 kW/m³ |
| Superficial gas velocity | 0.010000 m/s |
| Liquid type | Coalescing (pure water, simple media) |
Applying the formula below gives:
| Result | Value |
|---|---|
| kLa from the readings | 116.94 1/h |
| kLa by van 't Riet | 148.35 1/h |
| Maximum oxygen transfer rate at C = 0 | 0.87702 kg/(m³·h) |
Open this example in the calculator and change any input.
Formula
\(\ln\frac{C^* - C_1}{C^* - C_2} = k_La(t_2 - t_1)\)
\(k_La = 0.026\left(\frac{P}{V}\right)^{0.4}v_s^{0.5}\ \text{(coalescing)}, \quad 0.002\left(\frac{P}{V}\right)^{0.7}v_s^{0.2}\ \text{(non-coalescing)}\ \ (\mathrm{SI})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C^*\) | Saturation dissolved oxygen | kg/m³ |
| \(C_1\) | Dissolved oxygen at t₁ | kg/m³ |
| \(C_2\) | Dissolved oxygen at t₂ | kg/m³ |
| \(t_2 - t_1\) | Time between the readings | s |
| \(P/V\) | Gassed power per volume | W/m³ |
| \(v_s\) | Superficial gas velocity | m/s |
| \(\text{liquid}\) | Liquid type | - |
| \(k_La\) | kLa from the readings | 1/s |
| \(k_La_{vR}\) | kLa by van 't Riet | 1/s |
| \(OTR_{max}\) | Maximum oxygen transfer rate at C = 0 | kg/(m³·s) |
Method and standards
Dynamic method; van 't Riet correlations.
Where it is used
- Fermenter and aeration tank testing.
- Scale-up checks.
Common mistakes
- Ignoring probe lag.
- Using readings near saturation.
Assumptions and limits
- Well-mixed liquid; constant C*.
- The two-point form holds when the liquid takes up no oxygen during re-aeration (water or broth without respiring cells). With a respiring culture the balance is dC/dt = kLa(C* − C) − OUR, and the oxygen uptake rate must be included.
- Van 't Riet's correlations come from vessels up to 2.6 m³ over their own ranges of power input and gas velocity; at larger scale or far outside those conditions treat the estimate as indicative only.
References
- Doran
- Bioprocess Engineering Principles
- 2nd ed. (Academic Press, 2013)
- ch. 10 (oxygen transfer, dynamic method)
- van 't Riet (1979)
- Ind. Eng. Chem. Process Des. Dev. 18: 357
Questions and answers
How is the test done?
Strip the oxygen with nitrogen (or stop the air), then restart aeration and log the dissolved-oxygen rise; ln(C* − C) falls linearly with time at slope −kLa.
Why does the liquid type matter?
Salts and broth components stop bubbles coalescing, giving smaller bubbles and higher kLa at the same power.
What do the defaults give?
DO rising from 2 to 6 mg/L in 40 s at C* 7.5 mg/L: kLa about 117 /h; van 't Riet gives about 150 /h at 1 kW/m³ and 1 cm/s.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.