FireCADCalc

Evaporation Pond Area for Effluent or Brine

Surface area of a solar evaporation pond for a daily effluent volume from pan evaporation, pan coefficient, rainfall and a salinity factor.

Inputs

Examples: Illustrative 50 m3/day RO rejectArid siteSmall plant, humid climate

Accepted: 0.01 to 100,000 m³
Accepted: 0.1 to 30
Accepted: 50 to 100 %
Accepted: 0 to 30
Accepted: 30 to 100 %

Results

A pond loses water at the lake evaporation rate, about 0.7 times the pan evaporation, less for saline water as dissolved salts lower the vapour pressure, and gains the rainfall falling on it. The net rate times the area must match the effluent added. Design on the worst (monsoon or winter) month, not the annual average, and add freeboard and storage for wet periods.

Net evaporation (mm per day)4.5625
Pond surface area21,918m²
Pond area2.1918ha

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 50 m3/day RO reject. The inputs, in the units selected above:

InputValue
Effluent to evaporate per day50.000 m³
Pan evaporation (mm per day)6.0000 -
Pan coefficient70.000 %
Average rainfall (mm per day)2.0000 -
Salinity reduction factor of evaporation80.000 %

Applying the formula below gives:

ResultValue
Net evaporation (mm per day)1.3600
Pond surface area36,765 m²
Pond area3.6765 ha

Open this example in the calculator and change any input.

Formula

\(E_n = k_p E_p f_s - R, \quad A = \frac{Q}{E_n}\)

Variables

Symbol Meaning SI unit
\(Q\) Effluent to evaporate per day m³
\(E_p\) Pan evaporation (mm per day) -
\(k_p\) Pan coefficient -
\(R\) Average rainfall (mm per day) -
\(f_s\) Salinity reduction factor of evaporation -
\(E_n\) Net evaporation (mm per day) -
\(A\) Pond surface area m²
\(A_{ha}\) Pond area m²

Method and standards

Evaporation pond.

Where it is used

  • ZLD and RO reject disposal.
  • Mining and industrial effluent ponds.

Common mistakes

  • Using annual average evaporation.
  • Ignoring rainfall on the pond.

Assumptions and limits

  • Average rates over the design period.

References

  • Water balance of evaporation ponds with pan coefficient

Questions and answers

How big a pond for 50 m³/day?

With 6 mm/day pan evaporation, coefficient 0.7, salinity factor 0.8 and 2 mm/day rain, about 3.7 ha.

Why use the worst month?

Evaporation can fall below rainfall in the monsoon; the pond must store the excess.

What do the defaults represent?

An illustrative 50 m³/day of RO reject, 6 mm/day pan evaporation, 2 mm/day rain.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.