Electrodialysis: Current, Power and Membrane Area

Current from Faraday's law for a TDS removal, stack power from its resistance, energy per cubic metre and membrane area per cell pair from the CD/N ratio.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Brackish 1,000 m3/d, 0.03 N, 300 pairsReuse 10,000 m3/d, 0.02 N, 600 pairs

Accepted: 0.0864 to 864,000 m³/d
Accepted: 0.0001 to 1
Accepted: 1 to 100 %
Accepted: 1 to 2,000
Accepted: 10 to 100 %
Accepted: 0.01 to 1,000 Ω
Accepted: 50 to 2,000
Accepted: 10 to 100 %

Results

Energy follows: power divided by y × Q_p. CD/N of 500-800 (mA/cm² per g-eq/L) avoids polarisation; the stack resistance comes from tests. Pumping energy is extra.

Current165.44A
Power164.22kW
Energy per m³0.43793kWh/m³
Current density140.00A/m²
Membrane area per cell pair1.1817m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Brackish 1,000 m3/d, 0.03 N, 300 pairs. The inputs, in the units selected above:

InputValue
Product water flow1,000.0 m³/d
Feed normality (g-eq/L)0.030000 -
Salt removal efficiency60.000 %
Cell pairs in the stack300.00 -
Current efficiency92.000 %
Stack resistance2.5000 Ω
Current density to normality ratio (mA/cm² per g-eq/L)600.00 -
Product water as a fraction of feed85.000 %

Applying the formula below gives:

ResultValue
Current72.830 A
Power13.261 kW
Energy per m³0.37442 kWh/m³
Current density180.00 A/m²
Membrane area per cell pair0.40461 m²

Open this example in the calculator and change any input.

Formula

\(i = \frac{FQ_pNE_r}{nE_c}, \quad P = Ri^2, \quad CD = (CD/N)\,N, \quad A = \frac{i}{CD}\)

Variables

Symbol Meaning SI unit
\(Q_p\) Product water flow m³/s
\(N\) Feed normality (g-eq/L) -
\(E_r\) Salt removal efficiency -
\(n\) Cell pairs in the stack -
\(E_c\) Current efficiency -
\(R\) Stack resistance Ω
\(CD/N\) Current density to normality ratio (mA/cm² per g-eq/L) -
\(y\) Product water as a fraction of feed -
\(i\) Current A
\(P\) Power W
\(e\) Energy per m³ J/m³
\(CD\) Current density A/m²
\(A\) Membrane area per cell pair m²

Method and standards

Faraday's law and Ohm's law for an ED stack.

Where it is used

  • Electrodialysis and EDR sizing for reuse.
  • Energy comparison with RO.

Common mistakes

  • Normality in mg/L.
  • Leaving out current efficiency.

Assumptions and limits

  • Constant resistance; one stack.

Questions and answers

Why does the current depend on the cell pairs?

Each equivalent of salt moved needs one faraday of charge in each cell pair it passes, but one current passes all pairs in series, so more pairs need less current for the same removal.

Is the energy per m³ of product or feed?

Divides the power by 0.9 × the 4,000 m³/d it uses in the current equation, which is neither the feed (4,000/0.9) nor the product (0.9 × 4,000 if 4,000 is the feed) consistently; the calculator follows its arithmetic, P/(yQ_p). Divide P by the flow you mean for another basis.

What do the defaults represent?

An illustrative case: Brackish 1,000 m3/d, 0.03 N, 300 pairs. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 11-8, eqs. 11-49 and 11-50 and Example 11-9

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.