FireCADCalc

Bar Screen Headloss, Clean and Partly Clogged

Headloss through a coarse bar screen from approach and through-bar velocities with clean and clogged discharge coefficients, and the effect of blinding.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Peak flow 0.9 and 1.0 m/s, 30 % blockedLow flow 0.4 and 0.6 m/s, clean

Accepted: 0.05 to 3 m/s
Accepted: 0.05 to 5 m/s
Accepted: 0 to 90 %
Accepted: 0.3 to 1
Accepted: 0.3 to 1

Results

Mechanically cleaned coarse screens are usually limited to about 150 mm of headloss; the rake starts on a differential level or a timer of about 15 min. Blocking half the open area doubles the through-bar velocity and raises the loss about sevenfold.

Headloss, clean screen14.567mm
Velocity through the clogged screen0.60000m/s
Headloss, clogged screen14.567mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Peak flow 0.9 and 1.0 m/s, 30 % blocked. The inputs, in the units selected above:

InputValue
Approach velocity in the channel0.90000 m/s
Velocity through the clean screen openings1.0000 m/s
Fraction of the open area blocked30.000 %
Discharge coefficient, clean screen0.70000 -
Discharge coefficient, clogged screen0.60000 -

Applying the formula below gives:

ResultValue
Headloss, clean screen13.839 mm
Velocity through the clogged screen1.4286 m/s
Headloss, clogged screen104.59 mm

Open this example in the calculator and change any input.

Formula

\(h_L = \frac{1}{C}\,\frac{v_s^2 - v^2}{2g}, \quad v_s' = \frac{v_s}{1 - f_b}\)

Variables

Symbol Meaning SI unit
\(v\) Approach velocity in the channel m/s
\(v_s\) Velocity through the clean screen openings m/s
\(f_b\) Fraction of the open area blocked -
\(C\) Discharge coefficient, clean screen -
\(C'\) Discharge coefficient, clogged screen -
\(h_L\) Headloss, clean screen m
\(v_s'\) Velocity through the clogged screen m/s
\(h_L'\) Headloss, clogged screen m

Method and standards

Orifice-type headloss for bar screens.

Where it is used

  • Screen channel hydraulic profile.
  • Setting rake start levels.

Common mistakes

  • Using the channel velocity for both terms.
  • Forgetting that blinding raises the through-bar velocity.

Assumptions and limits

  • Coarse bar screens; fine screens have much higher losses.

Questions and answers

Why two coefficients?

Designers use about 0.7 for a clean screen and 0.6 once debris has built up, because the flow paths become more irregular.

How do I get the through-bar velocity?

Divide the flow by the clear open area between the bars below the water surface; keep it under about 1 m/s at peak flow so material is not forced through.

What do the defaults represent?

An illustrative case: Peak flow 0.9 and 1.0 m/s, 30 % blocked. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 5-1, eq. 5-1 and Example 5-1

Related calculators