Worked example
Example: 6308 ball bearing 30.7 kN at 4 kN, 1 450 rpm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Bearing type | Ball bearing (p = 3) |
| Basic dynamic load rating (catalogue) | 30.700 kN |
| Equivalent dynamic load | 4.0000 kN |
| Speed | 1,450.0 rpm |
| Life factor for reliability (1 for 90 %) | 1.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Load ratio | 7.6750 |
| Rating life, millions of revolutions | 452.10 |
| Rating life in operating hours | 5,196.6 h |
Open this example in the calculator and change any input.
Formula
\(L_{10} = a_1 \left(\frac{C}{P}\right)^p \ (10^6\ \text{rev}), \quad p = 3\ \text{ball}, \ \tfrac{10}{3}\ \text{roller}\)
\(L_{10h} = \frac{L_{10} \times 10^6}{n}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{type}\) | Bearing type | - |
| \(C\) | Basic dynamic load rating (catalogue) | N |
| \(P\) | Equivalent dynamic load | N |
| \(n\) | Speed | 1/s |
| \(a_1\) | Life factor for reliability (1 for 90 %) | - |
| \(C/P\) | Load ratio | - |
| \(L_{10}\) | Rating life, millions of revolutions | - |
| \(L_{10h}\) | Rating life in operating hours | s |
| \(p\) | Life exponent (3 ball, 10/3 roller) | - |
Method and standards
The Lundberg–Palmgren rating life used in bearing catalogues and in ISO 281's basic life; the reliability factor a₁ is entered by you from the maker's data.
Where it is used
- Choosing bearings for pumps, fans and motors.
- Checking whether a heavier load shortens life too much.
- Planning bearing replacement.
Common mistakes
- Using the static rating C₀ instead of the dynamic rating C.
- Forgetting to combine radial and axial loads into P.
- Ignoring lubrication and contamination, which often govern.
Assumptions and limits
- Basic life only: no a_ISO factor.
- Constant load and speed.
- A load above the dynamic rating C is flagged: the basic rating life does not apply there.
References
- Lundberg and Palmgren (1947, 1952); basic rating life of ISO 281
Questions and answers
How long does a 6308 bearing last at 4 kN and 1 450 rpm?
C/P = 7.68, so L10 = 452 million revolutions, about 5 200 hours.
Why does a roller bearing use 10/3?
Line contact makes life less sensitive to load than point contact; the exponent is 3 for ball and 10/3 for roller bearings.
What does L10 mean?
The life 90 % of a large group of identical bearings reach or exceed. For higher reliability multiply by the factor from the catalogue.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.