Induction Motor Synchronous Speed and Slip

Synchronous speed of an AC induction motor from supply frequency and poles, and the slip, slip speed and rotor frequency at the running speed.

Thermal power plantProcess steam and utilitiesElectric motorElectrician and wireman licence examinations

Inputs

Examples: 4-pole 50 Hz motor at 1 475 rpm6-pole 60 Hz motor at 1 170 rpm2-pole 50 Hz induction generator at 3 030 rpm

Results

Synchronous speed1,500.0rpm
Slip1.6667%
Slip speed25.000rpm
Rotor current frequency0.83333Hz

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 4-pole 50 Hz motor at 1 475 rpm. The inputs, in the units selected above:

InputValue
Supply frequency50.000 Hz
Number of poles4
Running (rotor) speed1,475.0 rpm

Applying the formula below gives:

ResultValue
Synchronous speed1,500.0 rpm
Slip1.6667 %
Slip speed25.000 rpm
Rotor current frequency0.83333 Hz

Open this example in the calculator and change any input.

Formula

\(n_s = \frac{120 f}{p} \ \text{rpm} \;\; (= 2f/p \ \text{rev/s})\)

\(s = \frac{n_s - n}{n_s}, \quad f_r = s f\)

Variables

Symbol Meaning SI unit
\(f\) supply frequency Hz
\(p\) number of poles -
\(n\) running speed rev/s
\(n_s\) synchronous speed rev/s
\(s\) slip -
\(n_s - n\) slip speed rev/s
\(f_r\) rotor current frequency Hz

Method and standards

The stator field turns once every p/2 cycles of the supply, so its speed is 2f/p revolutions per second (120 f/p in rpm). Slip is the rotor's lag behind the field as a share of synchronous speed; rotor currents alternate at slip times supply frequency.

Where it is used

  • Checking the load on a motor from its measured speed.
  • Choosing poles for a fan or pump speed.
  • Setting a VFD frequency for a target speed.

Common mistakes

  • Using 60 Hz speeds on a 50 Hz supply.
  • Counting pole pairs as poles (a 4-pole motor has 2 pole pairs).
  • Expecting a motor on a VFD to run exactly at f×120/p: it still slips.

Assumptions and limits

  • Induction motors; synchronous motors run at n_s with zero slip.
  • Steady running speed.

References

  • n_s = 120 f / p

Questions and answers

What is the speed of a 4-pole motor on 50 Hz?

The field turns at 1 500 rpm. A motor running at 1 475 rpm has 1.67 % slip, and its rotor currents are at 0.83 Hz.

Why does an induction motor never reach synchronous speed?

Torque needs rotor current, and rotor current needs the rotor to slip behind the field; slip grows roughly in proportion to load.

What does negative slip mean?

The rotor is driven faster than the field, so the machine feeds power back: it is running as an induction generator.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators