FireCADCalc

Transient Conduction in a Slab, Cylinder or Sphere (One-Term Series)

Centre and surface temperatures and heat removed from a plane wall, long cylinder or sphere suddenly exposed to convection, by the one-term series solution.

Food, dairy and textile

Inputs

Examples: Illustrative: steel plate 100 mm thick at 600 C, air blast 300 W/m2K at 30 C, 30 minSteel bar 60 mm diameter quenched in oil, 1500 W/m2K, 850 to 60 C, 2 minFood sphere 50 mm (k 0.55) heated in boiling water, 500 W/m2K, 15 min

Accepted: 0.1 to 5,000 mm
Accepted: 0.01 to 500 W/(m·K)
Accepted: 10 to 25,000 kg/m³
Accepted: 0.1 to 10 kJ/(kg·K)
Accepted: 0.1 to 1,000,000 W/(m²·K)
Accepted: -272.15 to 2,726.8 °C
Accepted: -272.15 to 2,726.8 °C
Accepted: 0.0016667 to 1,666,700 min

Results

One-term approximation of the exact series: within about 2 % for Fo > 0.2.

Biot number hL/k1.2857
Fourier number αt/L²0.99080
First eigenvalue1.3799
First coefficient1.2513
Dimensionless centre temperature0.18967
Centre temperature209.84°C
Surface temperature146.56°C
Fraction of the maximum heat transferred85.204%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: steel plate 100 mm thick at 600 C, air blast 300 W/m2K at 30 C, 30 min. The inputs, in the units selected above:

InputValue
ShapePlane wall (L = half-thickness)
Half-thickness or radius50.000 mm
Thermal conductivity40.000 W/(m·K)
Density7,800.0 kg/m³
Specific heat0.48000 kJ/(kg·K)
Surface heat transfer coefficient300.00 W/(m²·K)
Initial uniform temperature600.00 °C
Fluid temperature30.000 °C
Time30.000 min

Applying the formula below gives:

ResultValue
Biot number hL/k0.37500
Fourier number αt/L²7.6923
First eigenvalue0.57662
First coefficient1.0549
Dimensionless centre temperature0.081743
Centre temperature76.594 °C
Surface temperature69.060 °C
Fraction of the maximum heat transferred92.271 %

Open this example in the calculator and change any input.

Formula

\(\theta^* = \frac{T - T_\infty}{T_i - T_\infty} = C_1 e^{-\zeta_1^2 Fo}\,f(\zeta_1 x^*), \quad Bi = \frac{hL}{k}, \; Fo = \frac{\alpha t}{L^2}\)

\(\text{wall: } \zeta_1\tan\zeta_1 = Bi, \quad \text{cylinder: } \zeta_1\frac{J_1(\zeta_1)}{J_0(\zeta_1)} = Bi, \quad \text{sphere: } 1 - \zeta_1\cot\zeta_1 = Bi\)

Variables

Symbol Meaning SI unit
\(\text{shape}\) Shape -
\(L\) Half-thickness or radius m
\(k\) Thermal conductivity W/(m·K)
\(\rho\) Density kg/m³
\(c_p\) Specific heat J/(kg·K)
\(h\) Surface heat transfer coefficient W/(m²·K)
\(T_i\) Initial uniform temperature K
\(T_\infty\) Fluid temperature K
\(t\) Time s
\(Bi\) Biot number hL/k -
\(Fo\) Fourier number αt/L² -
\(\zeta_1\) First eigenvalue -
\(C_1\) First coefficient -
\(\theta_0^*\) Dimensionless centre temperature -
\(T_0\) Centre temperature K
\(T_s\) Surface temperature K
\(Q/Q_0\) Fraction of the maximum heat transferred -

Method and standards

One-term series solution of transient conduction with convection at the surface.

Where it is used

  • Heat treatment and quenching of plates, bars and balls.
  • Food sterilisation and chilling, cooling of castings.

Common mistakes

  • Using the full thickness of a wall instead of the half-thickness.
  • Using the result for Fo below 0.2.

Assumptions and limits

  • Constant properties, uniform initial temperature, uniform h, no heat generation.

References

  • One-term approximation of the exact series solutions (Heisler charts in equation form)

Questions and answers

When can I use this instead of the lumped method?

Whenever Bi exceeds about 0.1, so the interior temperature is not uniform; this solution then gives the centre and surface separately.

Why must Fo exceed 0.2?

At early times the higher terms of the series are still significant; after Fo ≈ 0.2 the first term dominates.

What do the defaults represent?

An illustrative 100 mm thick steel plate (half-thickness 50 mm) at 600 °C cooled in air-blast at 300 W/(m²·K) and 30 °C for 30 minutes.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Incropera, DeWitt, Bergman and Lavine, Fundamentals of Heat and Mass Transfer, 6th ed. (Wiley, 2007), sec. 5.5 and 5.6, Table 5.1

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.