Worked example
Example: Illustrative: steel plate 100 mm thick at 600 C, air blast 300 W/m2K at 30 C, 30 min. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Shape | Plane wall (L = half-thickness) |
| Half-thickness or radius | 50.000 mm |
| Thermal conductivity | 40.000 W/(m·K) |
| Density | 7,800.0 kg/m³ |
| Specific heat | 0.48000 kJ/(kg·K) |
| Surface heat transfer coefficient | 300.00 W/(m²·K) |
| Initial uniform temperature | 600.00 °C |
| Fluid temperature | 30.000 °C |
| Time | 30.000 min |
Applying the formula below gives:
| Result | Value |
|---|---|
| Biot number hL/k | 0.37500 |
| Fourier number αt/L² | 7.6923 |
| First eigenvalue | 0.57662 |
| First coefficient | 1.0549 |
| Dimensionless centre temperature | 0.081743 |
| Centre temperature | 76.594 °C |
| Surface temperature | 69.060 °C |
| Fraction of the maximum heat transferred | 92.271 % |
Open this example in the calculator and change any input.
Formula
\(\theta^* = \frac{T - T_\infty}{T_i - T_\infty} = C_1 e^{-\zeta_1^2 Fo}\,f(\zeta_1 x^*), \quad Bi = \frac{hL}{k}, \; Fo = \frac{\alpha t}{L^2}\)
\(\text{wall: } \zeta_1\tan\zeta_1 = Bi, \quad \text{cylinder: } \zeta_1\frac{J_1(\zeta_1)}{J_0(\zeta_1)} = Bi, \quad \text{sphere: } 1 - \zeta_1\cot\zeta_1 = Bi\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{shape}\) | Shape | - |
| \(L\) | Half-thickness or radius | m |
| \(k\) | Thermal conductivity | W/(m·K) |
| \(\rho\) | Density | kg/m³ |
| \(c_p\) | Specific heat | J/(kg·K) |
| \(h\) | Surface heat transfer coefficient | W/(m²·K) |
| \(T_i\) | Initial uniform temperature | K |
| \(T_\infty\) | Fluid temperature | K |
| \(t\) | Time | s |
| \(Bi\) | Biot number hL/k | - |
| \(Fo\) | Fourier number αt/L² | - |
| \(\zeta_1\) | First eigenvalue | - |
| \(C_1\) | First coefficient | - |
| \(\theta_0^*\) | Dimensionless centre temperature | - |
| \(T_0\) | Centre temperature | K |
| \(T_s\) | Surface temperature | K |
| \(Q/Q_0\) | Fraction of the maximum heat transferred | - |
Method and standards
One-term series solution of transient conduction with convection at the surface.
Where it is used
- Heat treatment and quenching of plates, bars and balls.
- Food sterilisation and chilling, cooling of castings.
Common mistakes
- Using the full thickness of a wall instead of the half-thickness.
- Using the result for Fo below 0.2.
Assumptions and limits
- Constant properties, uniform initial temperature, uniform h, no heat generation.
References
- One-term approximation of the exact series solutions (Heisler charts in equation form)
Questions and answers
When can I use this instead of the lumped method?
Whenever Bi exceeds about 0.1, so the interior temperature is not uniform; this solution then gives the centre and surface separately.
Why must Fo exceed 0.2?
At early times the higher terms of the series are still significant; after Fo ≈ 0.2 the first term dominates.
What do the defaults represent?
An illustrative 100 mm thick steel plate (half-thickness 50 mm) at 600 °C cooled in air-blast at 300 W/(m²·K) and 30 °C for 30 minutes.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Incropera, DeWitt, Bergman and Lavine, Fundamentals of Heat and Mass Transfer, 6th ed. (Wiley, 2007), sec. 5.5 and 5.6, Table 5.1