Plate-Fin Exchanger: Fin Efficiency and Overall Surface Efficiency

Fin efficiency of rectangular fins brazed between two plates, the finned share of the surface, the overall surface efficiency and fin mass per unit length.

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: Same with 0.06 mm copper finsAluminium 0.12 mm fins

Accepted: 1 to 50 mm
Accepted: 0.01 to 2 mm
Accepted: 1.27 to 76.2 1/in
Accepted: 1 to 10,000 W/(m²·K)
Accepted: 1 to 500 W/(m·K)
Accepted: 500 to 20,000 kg/m³

Results

Fins heated from both plates are treated as two fins of length ℓ = b/2 with an adiabatic mid-plane; fin edge area is neglected. Areas are per metre of flow length per metre of width of one passage.

Fin length, half the plate spacing12.000mm
Fin parameter (2h/(k_fδ))^½118.881/m
mℓ1.4265
Fin efficiency62.457%
Fin share of the total surface93.711%
Overall surface efficiency64.818%
Heat transfer area per unit flow length and width30.656
Fin mass per square metre of passage plan area7.7181kg/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Same with 0.06 mm copper fins. The inputs, in the units selected above:

InputValue
Plate spacing (fin height)24.000 mm
Fin thickness0.060000 mm
Fin density15.240 1/in
Heat transfer coefficient170.00 W/(m²·K)
Fin thermal conductivity401.00 W/(m·K)
Fin material density8,933.0 kg/m³

Applying the formula below gives:

ResultValue
Fin length, half the plate spacing12.000 mm
Fin parameter (2h/(k_fδ))^½118.88 1/m
mℓ1.4265
Fin efficiency62.457 %
Fin share of the total surface93.711 %
Overall surface efficiency64.818 %
Heat transfer area per unit flow length and width30.656
Fin mass per square metre of passage plan area7.7181 kg/m²

Open this example in the calculator and change any input.

Formula

\(\eta_f = \frac{\tanh(m\ell)}{m\ell}, \quad m = \left(\frac{2h}{k_f\delta}\right)^{1/2}, \quad \ell = \frac{b}{2}\)

\(\eta_o = 1 - \frac{A_f}{A}(1 - \eta_f)\)

Variables

Symbol Meaning SI unit
\(b\) Plate spacing (fin height) m
\(\delta\) Fin thickness m
\(n_f\) Fin density 1/m
\(h\) Heat transfer coefficient W/(m²·K)
\(k_f\) Fin thermal conductivity W/(m·K)
\(\rho_f\) Fin material density kg/m³
\(\ell\) Fin length, half the plate spacing m
\(m\) Fin parameter (2h/(k_fδ))^½ 1/m
\(m\ell\) mℓ -
\(\eta_f\) Fin efficiency -
\(A_f/A\) Fin share of the total surface -
\(\eta_o\) Overall surface efficiency -
\(A/W\) Heat transfer area per unit flow length and width -
\(m_{fin}\) Fin mass per square metre of passage plan area kg/m²

Method and standards

Straight rectangular fin with an adiabatic tip and the overall surface efficiency of a finned passage.

Where it is used

  • Plate-fin (brazed aluminium) exchangers.
  • Choosing fin thickness, density and material.

Common mistakes

  • Using the full plate spacing as the fin length.
  • Applying η_f to the whole surface instead of η_o.

Assumptions and limits

  • Uniform h; one-dimensional conduction in the fin.

Questions and answers

Why is the fin length half the plate spacing?

Both plates are heated (or cooled) equally, so the fin's mid-height is a line of symmetry with no heat flow, just like the tip of a fin of length b/2.

Copper or aluminium?

Aluminium has 59 % of copper's conductivity, so η_f drops (0.76 to 0.66 in Shah's example), but the fins weigh less than a third as much.

What do the defaults represent?

An illustrative case: Same with 0.06 mm copper fins. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Shah and Sekulić, Fundamentals of Heat Exchanger Design (Wiley, 2003), sec. 4.3, eqs. 4.134 and 4.158 and Example 4.3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.