FireCADCalc

Nucleate Boiling of Binary Mixtures: Schlünder, Thome–Shakir, Palen

Nucleate boiling coefficient of a binary mixture from the pure-component values, phase compositions or boiling range, and Palen's Mostinski correction.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Illustrative binary at 1 atm: x 0.40, y 0.62, 12 K boiling range, 30 kW/m2Narrow-boiling hydrocarbon cut: 3 K range, 50 kW/m2

Accepted: 0.1 to 99.9 %
Accepted: 0.1 to 99.9 %
Accepted: -223.15 to 426.85 °C
Accepted: -223.15 to 426.85 °C
Accepted: 10 to 1,000,000 W/(m²·K)
Accepted: 10 to 1,000,000 W/(m²·K)
Accepted: 0.01 to 10,000 kW/m²
Accepted: 0.1 to 100 kmol/m³
Accepted: 1 to 100 kJ/mol
Accepted: 0 to 200 K
Accepted: 1 to 100,000 kPa
Accepted: 100 to 100,000 kPa
Accepted: 100 to 100,000 kPa

Results

Schlünder needs the equilibrium vapour composition; Thome–Shakir uses the boiling range instead (mass transfer coefficients 0.0002 and 0.0003 m/s). Palen's factor applies only with the Mostinski correlation and is deliberately conservative.

Ideal mixture coefficient (x_i/h_i)⁻¹2,785.7W/(m²·K)
Schlünder2,661.9W/(m²·K)
Thome–Shakir2,552.0W/(m²·K)
Pseudo-reduced pressure0.15625
Pressure factor (Palen)1.5169
Mixture factor (Palen)0.79007
Mostinski with Palen's mixture factor2,550.4W/(m²·K)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative binary at 1 atm: x 0.40, y 0.62, 12 K boiling range, 30 kW/m2. The inputs, in the units selected above:

InputValue
Liquid mole fraction of the lighter component40.000 %
Vapour mole fraction of the lighter component62.000 %
Boiling point of the lighter component at the pressure68.750 °C
Boiling point of the heavier component at the pressure110.65 °C
Pure-component coefficient, lighter4,500.0 W/(m²·K)
Pure-component coefficient, heavier3,800.0 W/(m²·K)
Heat flux30.000 kW/m²
Liquid molar density8.0000 kmol/m³
Latent heat of the mixture31.000 kJ/mol
Boiling range T_dew − T_bubble12.000 K
Pressure101.33 kPa
Critical pressure, lighter3,030.0 kPa
Critical pressure, heavier2,740.0 kPa

Applying the formula below gives:

ResultValue
Ideal mixture coefficient (x_i/h_i)⁻¹4,052.1 W/(m²·K)
Schlünder2,589.1 W/(m²·K)
Thome–Shakir2,634.9 W/(m²·K)
Pseudo-reduced pressure0.035478
Pressure factor (Palen)0.86512
Mixture factor (Palen)0.58958
Mostinski with Palen's mixture factor701.80 W/(m²·K)

Open this example in the calculator and change any input.

Formula

\(h_{nb} = h_{ideal}\left\{1 + \frac{h_{ideal}}{\hat q}\left[1 - \exp\left(\frac{-\hat q}{\rho_L\lambda\beta}\right)\right](T_{sat,2} - T_{sat,1})(y_1 - x_1)\right\}^{-1}\)

\(h_{TS} = h_{ideal}\left\{1 + \frac{BR\,h_{ideal}}{\hat q}\left[1 - \exp\left(\frac{-\hat q}{\rho_L\lambda\beta}\right)\right]\right\}^{-1}, \quad F_m = \left(1 + 0.023\hat q^{0.15}BR^{0.75}\right)^{-1}\)

Variables

Symbol Meaning SI unit
\(x_1\) Liquid mole fraction of the lighter component -
\(y_1\) Vapour mole fraction of the lighter component -
\(T_{sat,1}\) Boiling point of the lighter component at the pressure K
\(T_{sat,2}\) Boiling point of the heavier component at the pressure K
\(h_{nb,1}\) Pure-component coefficient, lighter W/(m²·K)
\(h_{nb,2}\) Pure-component coefficient, heavier W/(m²·K)
\(\hat q\) Heat flux W/m²
\(\rho_L\) Liquid molar density mol/m³
\(\lambda\) Latent heat of the mixture J/mol
\(BR\) Boiling range T_dew − T_bubble K
\(P\) Pressure Pa
\(P_{c,1}\) Critical pressure, lighter Pa
\(P_{c,2}\) Critical pressure, heavier Pa
\(h_{ideal}\) Ideal mixture coefficient (x_i/h_i)⁻¹ W/(m²·K)
\(h_{Schl}\) Schlünder W/(m²·K)
\(h_{TS}\) Thome–Shakir W/(m²·K)
\(P_{pr}\) Pseudo-reduced pressure -
\(F_P\) Pressure factor (Palen) -
\(F_m\) Mixture factor (Palen) -
\(h_{Palen}\) Mostinski with Palen's mixture factor W/(m²·K)

Method and standards

Mixture corrections to nucleate pool boiling coefficients.

Where it is used

  • Reboilers on multicomponent columns.
  • Vaporisers for wide-boiling hydrocarbon mixtures.

Common mistakes

  • Using the mole-average of pure coefficients without the mixture correction.
  • Applying Palen's factor to correlations other than Mostinski.

Assumptions and limits

  • Binary mixtures (Schlünder); pool boiling.

References

  • Schlünder and Thome–Shakir mixture corrections to the ideal coefficient; Palen's Mostinski factor

Questions and answers

Why do mixtures boil worse than pure liquids?

The lighter component evaporates preferentially, leaving the liquid at the wall richer in the heavier one; its higher boiling point and the extra mass transfer resistance reduce the coefficient, often below either pure value.

Which method should I use?

Schlünder when the vapour–liquid equilibrium is known; Thome–Shakir for petroleum cuts with a known boiling range; Palen–Mostinski for a conservative design.

What do the defaults represent?

An illustrative binary of 40 % light component boiling at 1 atm with a 12 K boiling range, pure coefficients 4,500 and 3,800 W/(m²·K) and a heat flux of 30 kW/m².

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Serth, Process Heat Transfer: Principles and Applications (Academic Press, 2007), sec. 9.3.2, eqs. 9.14 to 9.18 and Example 9.2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.