FireCADCalc

Flow Boiling in Tubes: Chen and Liu–Winterton Coefficients

Convective boiling coefficient in a vertical tube by Chen (Forster–Zuber or Mostinski nucleate term) and by Liu–Winterton with Cooper's nucleate term.

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: Water at 1 atm in a 25 mm tube, 500 kg/(m2 s), x = 0.05, 8 K superheatRefrigerant-like fluid at high quality, 200 kg/(m2 s), x = 0.6, 5 K

Accepted: 1 to 10,000 kg/(m²·s)
Accepted: 2 to 200 mm
Accepted: 0 to 99 %
Accepted: 0.1 to 60 K
Accepted: 0.001 to 10,000 kPa
Accepted: 1 to 30,000 kPa
Accepted: 100 to 30,000 kPa
Accepted: 2 to 500 kg/kmol
Accepted: 50 to 2,000 kg/m³
Accepted: 0.01 to 500 kg/m³
Accepted: 0.001 to 1,000 mPa·s
Accepted: 1E-4 to 1 mPa·s
Accepted: 0.01 to 1 W/(m·K)
Accepted: 0.5 to 10 kJ/(kg·K)
Accepted: 0.1 to 100 mN/m
Accepted: 10 to 3,000 kJ/kg

Results

Vertical upflow. Chen: Dittus–Boelter liquid coefficient times F, plus the suppressed nucleate term. Liu–Winterton: asymptotic sum with Cooper's nucleate term; for horizontal tubes with Fr_LO < 0.05 apply the Froude corrections.

Re_L is below 10,000: the Dittus–Boelter liquid coefficient is outside its turbulent range.

Liquid-alone Reynolds number4,705.9
Liquid Prandtl number2.9750
Liquid-alone coefficient (Dittus–Boelter)246.79W/(m²·K)
Lockhart–Martinelli parameter0.18473
Chen enhancement factor8.3798
Chen suppression factor0.47106
Forster–Zuber nucleate coefficient5,704.7W/(m²·K)
Chen coefficient (Forster–Zuber)4,755.3W/(m²·K)
Chen coefficient with Mostinski–Palen nucleate term3,145.2W/(m²·K)
Heat flux, Chen–Mostinski15.726kW/m²
Liu–Winterton enhancement factor3.7011
Liu–Winterton suppression factor0.80479
Liu–Winterton coefficient3,529.2W/(m²·K)
Heat flux, Liu–Winterton17.646kW/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Water at 1 atm in a 25 mm tube, 500 kg/(m2 s), x = 0.05, 8 K superheat. The inputs, in the units selected above:

InputValue
Mass flux500.00 kg/(m²·s)
Tube inside diameter25.000 mm
Vapour mass fraction (quality)5.0000 %
Wall superheat T_w − T_sat8.0000 K
P_sat(T_w) − P_sat(T_sat)46.600 kPa
Pressure101.33 kPa
Critical pressure22,064 kPa
Molar mass18.015 kg/kmol
Liquid density958.40 kg/m³
Vapour density0.59800 kg/m³
Liquid viscosity0.28200 mPa·s
Vapour viscosity0.012300 mPa·s
Liquid thermal conductivity0.67900 W/(m·K)
Liquid specific heat4.2160 kJ/(kg·K)
Surface tension58.900 mN/m
Latent heat2,257.0 kJ/kg

Applying the formula below gives:

ResultValue
Liquid-alone Reynolds number42,110
Liquid Prandtl number1.7510
Liquid-alone coefficient (Dittus–Boelter)3,912.7 W/(m²·K)
Lockhart–Martinelli parameter0.48360
Chen enhancement factor4.3114
Chen suppression factor0.15342
Forster–Zuber nucleate coefficient8,646.6 W/(m²·K)
Chen coefficient (Forster–Zuber)18,196 W/(m²·K)
Chen coefficient with Mostinski–Palen nucleate term18,151 W/(m²·K)
Heat flux, Chen–Mostinski145.21 kW/m²
Liu–Winterton enhancement factor5.6555
Liu–Winterton suppression factor0.73565
Liu–Winterton coefficient24,747 W/(m²·K)
Heat flux, Liu–Winterton197.98 kW/m²

Open this example in the calculator and change any input.

Formula

\(h_b = S_{CH}h_{nb} + F(X_{tt})h_L, \quad F = 2.35\left(X_{tt}^{-1} + 0.213\right)^{0.736}, \quad S_{CH} = \left[1 + 2.53\times10^{-6}(Re_LF^{1.25})^{1.17}\right]^{-1}\)

\(h_{b,LW} = \left[(S_{LW}h_{nb})^2 + (E_{LW}h_L)^2\right]^{1/2}, \quad E_{LW} = \left[1 + xPr_L\frac{\rho_L - \rho_V}{\rho_V}\right]^{0.35}, \quad S_{LW} = \left(1 + 0.055E_{LW}^{0.1}Re_L^{0.16}\right)^{-1}\)

Variables

Symbol Meaning SI unit
\(G\) Mass flux kg/(m²·s)
\(D_i\) Tube inside diameter m
\(x\) Vapour mass fraction (quality) -
\(\Delta T_e\) Wall superheat T_w − T_sat K
\(\Delta P_{sat}\) P_sat(T_w) − P_sat(T_sat) Pa
\(P\) Pressure Pa
\(P_c\) Critical pressure Pa
\(M\) Molar mass kg/kmol
\(\rho_L\) Liquid density kg/m³
\(\rho_V\) Vapour density kg/m³
\(\mu_L\) Liquid viscosity Pa·s
\(\mu_V\) Vapour viscosity Pa·s
\(k_L\) Liquid thermal conductivity W/(m·K)
\(c_{p,L}\) Liquid specific heat J/(kg·K)
\(\sigma\) Surface tension N/m
\(\lambda\) Latent heat J/kg
\(Re_L\) Liquid-alone Reynolds number -
\(Pr_L\) Liquid Prandtl number -
\(h_L\) Liquid-alone coefficient (Dittus–Boelter) W/(m²·K)
\(X_{tt}\) Lockhart–Martinelli parameter -
\(F(X_{tt})\) Chen enhancement factor -
\(S_{CH}\) Chen suppression factor -
\(h_{nb,FZ}\) Forster–Zuber nucleate coefficient W/(m²·K)
\(h_b\) Chen coefficient (Forster–Zuber) W/(m²·K)
\(h_b'\) Chen coefficient with Mostinski–Palen nucleate term W/(m²·K)
\(\hat q'\) Heat flux, Chen–Mostinski W/m²
\(E_{LW}\) Liu–Winterton enhancement factor -
\(S_{LW}\) Liu–Winterton suppression factor -
\(h_{b,LW}\) Liu–Winterton coefficient W/(m²·K)
\(\hat q_{LW}\) Heat flux, Liu–Winterton W/m²

Method and standards

Superposition and asymptotic models of convective plus nucleate boiling in tubes.

Where it is used

  • Thermosyphon and forced-circulation reboilers.
  • Evaporator tube design.

Common mistakes

  • Using the total flow in Re_L.
  • Using the pool-boiling form of Mostinski (fixed ΔT) inside Chen, which must be solved with the flow-boiling heat flux.

Assumptions and limits

  • Saturated boiling below dryout; vertical tubes.

Questions and answers

Why is the Liu–Winterton result so much higher?

Its nucleate term is Cooper's correlation, which predicts far more nucleate boiling than Forster–Zuber or Mostinski for this fluid.

What do the defaults represent?

An illustrative case: Water at 1 atm in a 25 mm tube, 500 kg/(m2 s), x = 0.05, 8 K superheat. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Serth, Process Heat Transfer: Principles and Applications (Academic Press, 2007), sec. 9.5, eqs. 9.68 to 9.82 and Example 9.7 (Chen 1966; Liu and Winterton 1991)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.