FireCADCalc

Ozone Contactor CT and Log Inactivation

CT of a multi-compartment ozone contactor from first-order ozone decay and t10/t, and the log inactivation from the coefficient of specific lethality.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Virus credit, 1 mg/L, 0.2/min, 3 x 4 min, t10/t 0.5

Accepted: 0.1 to 50 mg/L
Accepted: 0 to 60 1/min
Accepted: 0.1 to 60 min
Accepted: 1 to 20
Accepted: 10 to 100 %
Accepted: 0.001 to 100

Results

CT in mg·min/L uses each compartment's outlet residual times its t10. The first compartment meets the immediate ozone demand and is left out. The specific lethality for Cryptosporidium is 0.256 L/mg·min (base 10) at 20 °C; it falls sharply in colder water.

CT of the reaction compartments1.4839
Log inactivation2.3742
Residual leaving the last compartment0.090718mg/L

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Virus credit, 1 mg/L, 0.2/min, 3 x 4 min, t10/t 0.5. The inputs, in the units selected above:

InputValue
Ozone residual leaving the first compartment1.0000 mg/L
Ozone decay rate0.20000 1/min
Detention time of each compartment4.0000 min
Reaction compartments after the first3.0000 -
Baffling factor t10/t50.000 %
Coefficient of specific lethality (base 10, L/(mg·min))1.6000 -

Applying the formula below gives:

ResultValue
CT of the reaction compartments1.4839
Log inactivation2.3742
Residual leaving the last compartment0.090718 mg/L

Open this example in the calculator and change any input.

Formula

\(C_i = C_1e^{-k\,t_c\,i}, \quad CT = \sum_{i=1}^{n}C_i\,t_c\frac{t_{10}}{t}, \quad \log\frac{N_o}{N} = \Lambda\cdot CT\)

Variables

Symbol Meaning SI unit
\(C_1\) Ozone residual leaving the first compartment kg/m³
\(k\) Ozone decay rate 1/s
\(t_c\) Detention time of each compartment s
\(n\) Reaction compartments after the first -
\(t_{10}/t\) Baffling factor t10/t -
\(\Lambda\) Coefficient of specific lethality (base 10, L/(mg·min)) -
\(CT\) CT of the reaction compartments -
\(\log(N_o/N)\) Log inactivation -
\(C_n\) Residual leaving the last compartment kg/m³

Method and standards

Ozone CT by compartments with first-order decay.

Where it is used

  • Ozone disinfection design for reuse.
  • Checking log credits.

Common mistakes

  • Counting the first (demand) compartment.
  • Using t instead of t10.

Assumptions and limits

  • First-order ozone decay; Chick-Watson inactivation.

Questions and answers

Why multiply by t10/t?

Regulatory CT credit uses t10, the time by which 10 % of a tracer has passed, to allow for short-circuiting; 0.6 is typical of a well-baffled over-under contactor.

What do the defaults represent?

An illustrative case: Virus credit, 1 mg/L, 0.2/min, 3 x 4 min, t10/t 0.5. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 12-7, eq. 12-6 and Example 12-10

Related calculators