FireCADCalc

Discrete Particle Removal in an Ideal Settling Basin

Fraction of particles removed in an ideal sedimentation basin from a settling-velocity distribution of up to eight classes and the overflow rate.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Same suspension at 1.2 m/hFine solids, 1 m/h, 0.25 m/h classes

Accepted: 0.0036 to 36 m/h
Accepted: 0.0036 to 36 m/h
Accepted: 0 to 1E+12
Accepted: 0 to 1E+12
Accepted: 0 to 1E+12
Accepted: 0 to 1E+12
Accepted: 0 to 1E+12
Accepted: 0 to 1E+12
Accepted: 0 to 1E+12
Accepted: 0 to 1E+12

Results

Classes run from zero upwards in equal steps; each is represented by its mid-point velocity. Particles faster than the overflow rate are all removed; slower ones in the ratio v/v_c (Hazen's ideal basin). Real basins remove less because of turbulence, short-circuiting and density currents.

Fraction of particles removed91.500%
Particles in500.00
Particles removed457.50
Particles remaining in the effluent42.500

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Same suspension at 1.2 m/h. The inputs, in the units selected above:

InputValue
Overflow rate (critical velocity)1.2000 m/h
Width of each velocity class0.50000 m/h
Particles in class 1 (lowest velocities)30.000 -
Particles in class 250.000 -
Particles in class 390.000 -
Particles in class 4110.00 -
Particles in class 5100.00 -
Particles in class 670.000 -
Particles in class 730.000 -
Particles in class 820.000 -

Applying the formula below gives:

ResultValue
Fraction of particles removed91.500 %
Particles in500.00
Particles removed457.50
Particles remaining in the effluent42.500

Open this example in the calculator and change any input.

Formula

\(R = \frac{\sum_i \min\!\left(1, \dfrac{v_{n_i}}{v_c}\right)n_i}{\sum_i n_i}\)

Variables

Symbol Meaning SI unit
\(v_c\) Overflow rate (critical velocity) m/s
\(\Delta v\) Width of each velocity class m/s
\(n_1\) Particles in class 1 (lowest velocities) -
\(n_2\) Particles in class 2 -
\(n_3\) Particles in class 3 -
\(n_4\) Particles in class 4 -
\(n_5\) Particles in class 5 -
\(n_6\) Particles in class 6 -
\(n_7\) Particles in class 7 -
\(n_8\) Particles in class 8 -
\(R\) Fraction of particles removed -
\(\sum n_i\) Particles in -
\(\sum n_r\) Particles removed -
\(\sum n_e\) Particles remaining in the effluent -

Method and standards

Ideal (Hazen) settling basin for discrete particles.

Where it is used

  • Interpreting settling-column tests.
  • Choosing an overflow rate.

Common mistakes

  • Using the upper class limit instead of the mid-point.
  • Applying it to flocculent suspensions, which need isopercent curves.

Assumptions and limits

  • Discrete, non-flocculating particles; quiescent ideal basin.

Questions and answers

Why does depth not appear?

In an ideal basin a particle is removed if its settling velocity exceeds the overflow rate Q/A; depth cancels out, which is why surface area governs clarifier design.

Can I use mass instead of particle numbers?

Yes: enter the mass (or percentage) in each velocity class and the result is the fraction of mass removed.

What do the defaults represent?

An illustrative case: Same suspension at 1.2 m/h. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 5-4, eq. 5-30 and Example 5-5

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.