Disinfection Contact Time with Temperature Correction (Chick-Watson)

Contact time for a log kill at a disinfectant residual from the coefficient of specific lethality, corrected from one temperature to another by van't Hoff-Arrhenius.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Same water, 3-log, 5 to 25 CChloramine n = 1.2, 15 to 5 C

Accepted: 0.0001 to 1,000
Accepted: 0.3 to 3
Accepted: 0.001 to 50 mg/L
Accepted: 0.1 to 10
Accepted: 0 to 50 °C
Accepted: 0 to 50 °C
Accepted: 1 to 200 kJ/mol

Results

Chick-Watson in base-10 form: log(N/N₀) = −Λ Cⁿ t. The activation energy depends on the disinfectant and pH; warmer water disinfects faster.

Coefficient at the design temperature0.37778
Contact time at T₁1.5368min
Contact time at T₂3.2545min
CT at T₂ (mg·min/L)4.8817

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Same water, 3-log, 5 to 25 C. The inputs, in the units selected above:

InputValue
Coefficient of specific lethality at T₁ (L/mg·min, base 10)10.500 -
Coefficient of dilution1.0000 -
Disinfectant residual0.050000 mg/L
Log inactivation required3.0000 -
Temperature of the known coefficient5.0000 °C
Design temperature25.000 °C
Activation energy26.800 kJ/mol

Applying the formula below gives:

ResultValue
Coefficient at the design temperature22.845
Contact time at T₁5.7143 min
Contact time at T₂2.6264 min
CT at T₂ (mg·min/L)0.13132

Open this example in the calculator and change any input.

Formula

\(\log\frac{N}{N_o} = -\Lambda C^nt, \quad \ln\frac{\Lambda_2}{\Lambda_1} = \frac{E(T_2 - T_1)}{RT_1T_2}\)

Variables

Symbol Meaning SI unit
\(\Lambda_1\) Coefficient of specific lethality at T₁ (L/mg·min, base 10) -
\(n\) Coefficient of dilution -
\(C\) Disinfectant residual kg/m³
\(\log(N_o/N)\) Log inactivation required -
\(T_1\) Temperature of the known coefficient K
\(T_2\) Design temperature K
\(E\) Activation energy J/mol
\(\Lambda_2\) Coefficient at the design temperature -
\(t_1\) Contact time at T₁ s
\(t_2\) Contact time at T₂ s
\(CT_2\) CT at T₂ (mg·min/L) -

Method and standards

Chick-Watson with van't Hoff-Arrhenius temperature correction.

Where it is used

  • Seasonal contact time checks.
  • Comparing disinfectants.

Common mistakes

  • Mixing natural and base-10 logarithms.
  • Using °C in the Arrhenius term.

Assumptions and limits

  • Constant residual over the contact time.

Questions and answers

How much does temperature matter?

With E = 26,800 J/mol the coefficient nearly doubles from 5 to 20 °C, so winter governs the contact tank size.

What do the defaults represent?

An illustrative case: Same water, 3-log, 5 to 25 C. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 12-2, eqs. 12-5 and 12-7 and Example 12-2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.