Diffused Air for Post-aeration of Effluent (Plug Flow)

Air flow to raise effluent dissolved oxygen in a plug-flow post-aeration channel, from saturation, transfer efficiency and temperature (log-mean driving force).

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: With the 1.1 factor, 25 CFine-pore, 40,000 m3/d, 2 to 6 mg/L

Accepted: 0.864 to 4,320,000 m³/d
Accepted: 1 to 20 mg/L
Accepted: 0 to 20 mg/L
Accepted: 0 to 20 mg/L
Accepted: 1 to 50 %
Accepted: 0 to 40 °C
Accepted: 1 to 1.4 kg/m³
Accepted: 20 to 25 %
Accepted: 1 to 2

Results

The logarithm comes from integrating the transfer rate along the channel, where the oxygen deficit falls from C_s − C_i to C_s − C_o. Designers suggest multiplying by about 1.1 because wastewater saturates at about 95 % of clean water and transfers less readily.

Air flow0.85366m³/min
Oxygen dissolved13.300kg/d
Air-to-water ratio0.32349m³/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: With the 1.1 factor, 25 C. The inputs, in the units selected above:

InputValue
Effluent flow3,800.0 m³/d
Saturation DO at 20 °C9.0900 mg/L
DO entering1.5000 mg/L
DO required leaving5.0000 mg/L
Oxygen transfer efficiency6.0000 %
Water temperature25.000 °C
Air density1.2300 kg/m³
Oxygen mass fraction of air23.000 %
Safety factor for wastewater saturation and transfer (about 1.1)1.1000 -

Applying the formula below gives:

ResultValue
Air flow0.85366 m³/min
Oxygen dissolved13.300 kg/d
Air-to-water ratio0.32349 m³/m³

Open this example in the calculator and change any input.

Formula

\(Q_a = \frac{f}{\rho_aw_{O_2}}\,\frac{Q\,C_{s,20}}{E(1.024)^{T-20}}\ln\frac{C_s - C_i}{C_s - C_o}\)

Variables

Symbol Meaning SI unit
\(Q\) Effluent flow m³/s
\(C_s\) Saturation DO at 20 °C kg/m³
\(C_i\) DO entering kg/m³
\(C_o\) DO required leaving kg/m³
\(E\) Oxygen transfer efficiency -
\(T\) Water temperature K
\(\rho_a\) Air density kg/m³
\(w_{O_2}\) Oxygen mass fraction of air -
\(f\) Safety factor for wastewater saturation and transfer (about 1.1) -
\(Q_a\) Air flow m³/s
\(\dot m_{O_2}\) Oxygen dissolved kg/s
\(Q_a/Q\) Air-to-water ratio m³/m³

Method and standards

Plug-flow oxygen transfer with a log-mean deficit.

Where it is used

  • Post-aeration before discharge.
  • Sizing blowers for reaeration channels.

Common mistakes

  • Using the simple deficit for a long channel.
  • Forgetting the transfer efficiency.

Assumptions and limits

  • Plug flow; E at the diffuser depth; T in °C.

Questions and answers

Why a log term rather than the simple deficit?

In plug flow the deficit, and so the transfer rate, falls along the channel; integrating gives the logarithmic mean.

What do the defaults represent?

An illustrative case: With the 1.1 factor, 25 C. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 5-11, Example 5-15

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.