Worked example
Example: With the 1.1 factor, 25 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Effluent flow | 3,800.0 m³/d |
| Saturation DO at 20 °C | 9.0900 mg/L |
| DO entering | 1.5000 mg/L |
| DO required leaving | 5.0000 mg/L |
| Oxygen transfer efficiency | 6.0000 % |
| Water temperature | 25.000 °C |
| Air density | 1.2300 kg/m³ |
| Oxygen mass fraction of air | 23.000 % |
| Safety factor for wastewater saturation and transfer (about 1.1) | 1.1000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Air flow | 0.85366 m³/min |
| Oxygen dissolved | 13.300 kg/d |
| Air-to-water ratio | 0.32349 m³/m³ |
Open this example in the calculator and change any input.
Formula
\(Q_a = \frac{f}{\rho_aw_{O_2}}\,\frac{Q\,C_{s,20}}{E(1.024)^{T-20}}\ln\frac{C_s - C_i}{C_s - C_o}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Effluent flow | m³/s |
| \(C_s\) | Saturation DO at 20 °C | kg/m³ |
| \(C_i\) | DO entering | kg/m³ |
| \(C_o\) | DO required leaving | kg/m³ |
| \(E\) | Oxygen transfer efficiency | - |
| \(T\) | Water temperature | K |
| \(\rho_a\) | Air density | kg/m³ |
| \(w_{O_2}\) | Oxygen mass fraction of air | - |
| \(f\) | Safety factor for wastewater saturation and transfer (about 1.1) | - |
| \(Q_a\) | Air flow | m³/s |
| \(\dot m_{O_2}\) | Oxygen dissolved | kg/s |
| \(Q_a/Q\) | Air-to-water ratio | m³/m³ |
Method and standards
Plug-flow oxygen transfer with a log-mean deficit.
Where it is used
- Post-aeration before discharge.
- Sizing blowers for reaeration channels.
Common mistakes
- Using the simple deficit for a long channel.
- Forgetting the transfer efficiency.
Assumptions and limits
- Plug flow; E at the diffuser depth; T in °C.
Questions and answers
Why a log term rather than the simple deficit?
In plug flow the deficit, and so the transfer rate, falls along the channel; integrating gives the logarithmic mean.
What do the defaults represent?
An illustrative case: With the 1.1 factor, 25 C. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 5-11, Example 5-15