Aerobic Digester Volume, Oxygen and Air Requirement

Aerobic digester sludge flow and volume from SRT, volatile solids destroyed, oxygen at 2.3 kg per kg VSS, and air with oxygen transfer efficiency.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Small plant 300 kg/d at 2 %, 40 d

Accepted: 8.64 to 8,640,000 kg/d
Accepted: 0.2 to 10 %
Accepted: 1 to 1.2
Accepted: 1 to 231.48 d
Accepted: 30 to 95 %
Accepted: 5 to 80 %
Accepted: 1 to 3 kg/kg
Accepted: 1 to 1.4 kg/m³
Accepted: 2 to 50 %
Accepted: 0 to 40 °C

Results

Take the volatile solids reduction in the degree-day curve (about 45 % at 900 °C·d, 50 % at 1,500 °C·d). Air is 23.2 % oxygen by mass. If the air per volume is below the mixing range (about 0.02-0.04 m³/min·m³ for diffused air), mixing governs the blower size.

Sludge flow14.706m³/d
Digester volume588.24m³
VSS destroyed90.000kg/d
Oxygen required207.00kg/d
Air at standard conditions741.06m³/d
Air supplied6.4328m³/min
Air per digester volume0.0109361/min
Degree-days800.00

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Small plant 300 kg/d at 2 %, 40 d. The inputs, in the units selected above:

InputValue
Waste sludge to the digester (dry)300.00 kg/d
Thickened sludge solids2.0000 %
Sludge specific gravity1.0200 -
Solids retention time40.000 d
Volatile fraction of the sludge75.000 %
Volatile solids reduction (from degree-days)40.000 %
Oxygen per VSS destroyed2.3000 kg/kg
Air density at standard conditions1.2040 kg/m³
Oxygen transfer efficiency8.0000 %
Liquid temperature (for degree-days)20.000 °C

Applying the formula below gives:

ResultValue
Sludge flow14.706 m³/d
Digester volume588.24 m³
VSS destroyed90.000 kg/d
Oxygen required207.00 kg/d
Air at standard conditions741.06 m³/d
Air supplied6.4328 m³/min
Air per digester volume0.010936 1/min
Degree-days800.00

Open this example in the calculator and change any input.

Formula

\(Q = \frac{M}{\rho_wSG\,P_s}, \quad V = Q\cdot SRT, \quad O_2 = 2.3\,f_vR_{VS}M, \quad V_{air} = \frac{O_2}{0.232\rho_a}, \quad q = \frac{V_{air}}{OTE}\)

Variables

Symbol Meaning SI unit
\(M\) Waste sludge to the digester (dry) kg/s
\(P_s\) Thickened sludge solids -
\(SG\) Sludge specific gravity -
\(SRT\) Solids retention time s
\(f_v\) Volatile fraction of the sludge -
\(R_{VS}\) Volatile solids reduction (from degree-days) -
\(r_{O_2}\) Oxygen per VSS destroyed kg/kg
\(\rho_a\) Air density at standard conditions kg/m³
\(OTE\) Oxygen transfer efficiency -
\(T\) Liquid temperature (for degree-days) K
\(Q\) Sludge flow m³/s
\(V\) Digester volume m³
\(VSS_{red}\) VSS destroyed kg/s
\(O_2\) Oxygen required kg/s
\(V_{air}\) Air at standard conditions m³/s
\(q_{air}\) Air supplied m³/s
\(q_{air}/V\) Air per digester volume 1/s
\(T\cdot SRT\) Degree-days -

Method and standards

Aerobic digester design.

Where it is used

  • Aerobic digestion for small plants.
  • Blower sizing for digesters.

Common mistakes

  • Ignoring mixing.
  • Using the summer VSR for the winter volume.

Assumptions and limits

  • Single-stage complete mix; nitrification complete.

Questions and answers

Where does 2.3 kg O₂ per kg VSS come from?

Endogenous oxidation of cell mass (C₅H₇NO₂) to CO₂, water and nitrate needs about 2.3 kg of oxygen per kilogram of cells destroyed when nitrification is complete.

What do the defaults represent?

An illustrative case: Small plant 300 kg/d at 2 %, 40 d. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 13-10, Example 13-8 and Tables 13-44 and 13-45

Related calculators