Aerated Grit Chamber Sizing, Air Supply and Grit Quantity

Peak design flow, chamber volume and dimensions from detention time and width-to-depth ratio, average detention, diffuser air and daily grit volume.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Small plant 0.05 m3/s, one chamber, 4 minLarge plant 3 m3/s, four chambers, 2.5 min

Accepted: 0.36 to 180,000 m³/h
Accepted: 1 to 6
Accepted: 1 to 10
Accepted: 0.5 to 30 min
Accepted: 1 to 6 m
Accepted: 0.5 to 5
Accepted: 0.006 to 3 m³/(min·m)
Accepted: 0 to 1

Results

The typical values: 2-5 min detention at peak flow, depth 2-5 m, width-to-depth 1:1 to 5:1, air 0.2-0.5 m³/min per metre of length and 0.004-0.2 m³ of grit per 10³ m³ of wastewater. Two chambers let one be drained for maintenance.

Peak design flow6.6000m³/s
Volume of each chamber247.50m³
Width6.7500m
Length8.1481m
Detention at average flow5.5000min
Total air14.667m³/min
Grit removed20.736m³/d

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Small plant 0.05 m3/s, one chamber, 4 min. The inputs, in the units selected above:

InputValue
Average flow180.00 m³/h
Peaking factor for design3.0000 -
Number of chambers1.0000 -
Detention time at peak flow4.0000 min
Water depth2.5000 m
Width-to-depth ratio1.0000 -
Air per metre of chamber length0.40000 m³/(min·m)
Grit per volume of wastewater (m³ per 10³ m³)0.030000 -

Applying the formula below gives:

ResultValue
Peak design flow0.15000 m³/s
Volume of each chamber36.000 m³
Width2.5000 m
Length5.7600 m
Detention at average flow12.000 min
Total air2.3040 m³/min
Grit removed0.12960 m³/d

Open this example in the calculator and change any input.

Formula

\(Q_p = PF\cdot Q_{avg}, \quad V = \frac{Q_p}{n}t_p, \quad W = (W/d)\,d, \quad L = \frac{V}{Wd}, \quad Q_{air} = q_aLn\)

Variables

Symbol Meaning SI unit
\(Q_{avg}\) Average flow m³/s
\(PF\) Peaking factor for design -
\(n\) Number of chambers -
\(t_p\) Detention time at peak flow s
\(d\) Water depth m
\(W/d\) Width-to-depth ratio -
\(q_a\) Air per metre of chamber length m³/(s·m)
\(g_r\) Grit per volume of wastewater (m³ per 10³ m³) -
\(Q_p\) Peak design flow m³/s
\(V\) Volume of each chamber m³
\(W\) Width m
\(L\) Length m
\(t_a\) Detention at average flow s
\(Q_{air}\) Total air m³/s
\(V_g\) Grit removed m³/s

Method and standards

Aerated grit chamber design.

Where it is used

  • Preliminary treatment design.
  • Checking an existing chamber for higher flows.

Common mistakes

  • Designing on average flow.
  • Using the air per chamber as the total.

Assumptions and limits

  • Typical-value design; grit quantity varies widely with sewer system.

Questions and answers

Why design on peak flow?

Grit must settle at the highest sustained flow; the chamber then simply has a longer detention at average flow.

How is the air rate chosen?

The air sets the spiral roll that keeps organics in suspension while grit falls out; it is quoted per metre of chamber length, 0.2-0.5 m³/min·m, and should be adjustable.

What do the defaults represent?

An illustrative case: Small plant 0.05 m3/s, one chamber, 4 min. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 5-5, Example 5-8 and Table 5-16

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.