Worked example
Example: Small plant 0.05 m3/s, one chamber, 4 min. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Average flow | 180.00 m³/h |
| Peaking factor for design | 3.0000 - |
| Number of chambers | 1.0000 - |
| Detention time at peak flow | 4.0000 min |
| Water depth | 2.5000 m |
| Width-to-depth ratio | 1.0000 - |
| Air per metre of chamber length | 0.40000 m³/(min·m) |
| Grit per volume of wastewater (m³ per 10³ m³) | 0.030000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Peak design flow | 0.15000 m³/s |
| Volume of each chamber | 36.000 m³ |
| Width | 2.5000 m |
| Length | 5.7600 m |
| Detention at average flow | 12.000 min |
| Total air | 2.3040 m³/min |
| Grit removed | 0.12960 m³/d |
Open this example in the calculator and change any input.
Formula
\(Q_p = PF\cdot Q_{avg}, \quad V = \frac{Q_p}{n}t_p, \quad W = (W/d)\,d, \quad L = \frac{V}{Wd}, \quad Q_{air} = q_aLn\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_{avg}\) | Average flow | m³/s |
| \(PF\) | Peaking factor for design | - |
| \(n\) | Number of chambers | - |
| \(t_p\) | Detention time at peak flow | s |
| \(d\) | Water depth | m |
| \(W/d\) | Width-to-depth ratio | - |
| \(q_a\) | Air per metre of chamber length | m³/(s·m) |
| \(g_r\) | Grit per volume of wastewater (m³ per 10³ m³) | - |
| \(Q_p\) | Peak design flow | m³/s |
| \(V\) | Volume of each chamber | m³ |
| \(W\) | Width | m |
| \(L\) | Length | m |
| \(t_a\) | Detention at average flow | s |
| \(Q_{air}\) | Total air | m³/s |
| \(V_g\) | Grit removed | m³/s |
Method and standards
Aerated grit chamber design.
Where it is used
- Preliminary treatment design.
- Checking an existing chamber for higher flows.
Common mistakes
- Designing on average flow.
- Using the air per chamber as the total.
Assumptions and limits
- Typical-value design; grit quantity varies widely with sewer system.
Questions and answers
Why design on peak flow?
Grit must settle at the highest sustained flow; the chamber then simply has a longer detention at average flow.
How is the air rate chosen?
The air sets the spiral roll that keeps organics in suspension while grit falls out; it is quoted per metre of chamber length, 0.2-0.5 m³/min·m, and should be adjustable.
What do the defaults represent?
An illustrative case: Small plant 0.05 m3/s, one chamber, 4 min. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.