Complete-mix Activated Sludge Design by Monod Kinetics

Effluent soluble COD, aeration time for a target MLVSS, sludge production as VSS and TSS, biomass fraction, observed yield and oxygen demand at a chosen SRT.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Extended aeration 20 d SRT, 3,500 g/m3Short SRT 3 d, 2,000 g/m3

Accepted: 0.0864 to 1,728,000 m³/d
Accepted: 1 to 50,000 mg/L
Accepted: 0 to 10,000 mg/L
Accepted: 0 to 10,000 mg/L
Accepted: 1 to 115.74 d
Accepted: 300 to 20,000 mg/L
Accepted: 0.5 to 50
Accepted: 0.1 to 1,000 mg/L
Accepted: 0.05 to 1
Accepted: 0 to 1
Accepted: 0 to 50 %
Accepted: 50 to 100 %

Results

Complete-mix reactor with recycle; the influent biodegradable particulate COD is taken as part of the soluble COD (valid for SRT of 3 d or more). Nitrification is not included in the oxygen demand. Kinetic coefficients are at the design temperature.

Effluent soluble COD2.2405mg/L
Aeration time5.5384h
Aeration volume1,153.8m³
Sludge production as VSS769.22kg/d
Sludge production as TSS960.84kg/d
Active biomass fraction of the MLVSS0.64041
Observed yield, g VSS/g COD0.51667
Observed yield, g TSS/g COD0.64538
Oxygen required751.51kg/d

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Extended aeration 20 d SRT, 3,500 g/m3. The inputs, in the units selected above:

InputValue
Flow2,000.0 m³/d
Influent biodegradable soluble COD250.00 mg/L
Influent non-biodegradable VSS40.000 mg/L
Influent inert inorganic solids15.000 mg/L
Solids retention time20.000 d
Target MLVSS3,500.0 mg/L
Maximum substrate utilisation rate (g COD/g VSS·d)12.500 -
Half-velocity constant10.000 mg/L
Yield (g VSS/g COD)0.40000 -
Endogenous decay (1/d)0.10000 -
Fraction of biomass left as cell debris15.000 %
Biomass VSS/TSS ratio85.000 %

Applying the formula below gives:

ResultValue
Effluent soluble COD0.30928 mg/L
Aeration time11.421 h
Aeration volume951.77 m³
Sludge production as VSS166.56 kg/d
Sludge production as TSS211.83 kg/d
Active biomass fraction of the MLVSS0.39976
Observed yield, g VSS/g COD0.33353
Observed yield, g TSS/g COD0.42419
Oxygen required376.47 kg/d

Open this example in the calculator and change any input.

Formula

\(S = \frac{K_s(1 + b\,SRT)}{SRT(Yk - b) - 1}, \quad X_T\tau = \frac{Y(S_o - S)SRT}{1 + b\,SRT}\left(1 + f_db\,SRT\right) + X_{o,i}SRT\)

\(P_{X,VSS} = \frac{X_TV}{SRT}, \quad R_o = Q(S_o - S) - 1.42P_{X,bio}\)

Variables

Symbol Meaning SI unit
\(Q\) Flow m³/s
\(S_o\) Influent biodegradable soluble COD kg/m³
\(X_{o,i}\) Influent non-biodegradable VSS kg/m³
\(TSS_o - VSS_o\) Influent inert inorganic solids kg/m³
\(SRT\) Solids retention time s
\(X_T\) Target MLVSS kg/m³
\(k\) Maximum substrate utilisation rate (g COD/g VSS·d) -
\(K_s\) Half-velocity constant kg/m³
\(Y\) Yield (g VSS/g COD) -
\(b\) Endogenous decay (1/d) -
\(f_d\) Fraction of biomass left as cell debris -
\(VSS/TSS\) Biomass VSS/TSS ratio -
\(S\) Effluent soluble COD kg/m³
\(\tau\) Aeration time s
\(V\) Aeration volume m³
\(P_{X,VSS}\) Sludge production as VSS kg/s
\(P_{X,TSS}\) Sludge production as TSS kg/s
\(X/X_T\) Active biomass fraction of the MLVSS -
\(Y_{obs}\) Observed yield, g VSS/g COD -
\(Y_{obs,TSS}\) Observed yield, g TSS/g COD -
\(R_o\) Oxygen required kg/s

Method and standards

Monod-kinetics design of complete-mix suspended growth.

Where it is used

  • Activated sludge process design.
  • Checking the effect of SRT on sludge and oxygen.

Common mistakes

  • Using a total COD that includes the non-biodegradable part.
  • Forgetting the inert solids in P_X,TSS.

Assumptions and limits

  • Steady state; complete mix; no nitrification.

Questions and answers

Why design on SRT rather than HRT?

The SRT sets the effluent quality and sludge yield; the aeration time then follows from the MLVSS the clarifier can handle.

Why does the oxygen demand subtract 1.42 P_X,bio?

Every gram of biomass wasted carries 1.42 g of COD that was not oxidised, so it is removed from the COD balance.

What do the defaults represent?

An illustrative case: Extended aeration 20 d SRT, 3,500 g/m3. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 7-6, eqs. 7-42 to 7-61 and Example 7-6

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.