Worked example
Example: 50 kN, 20 mm rope, 600 mm sheave. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Load on the rope (including hook and rope weight) | 50.000 kN |
| Rope diameter | 20.000 mm |
| Metallic area as a share of the circle πd²/4 | 50.000 % |
| Outer wire diameter | 1.3000 mm |
| Sheave pitch diameter | 600.00 mm |
| Modulus of the rope | 83.000 GPa |
| Minimum breaking force of the rope | 260.00 kN |
Applying the formula below gives:
| Result | Value |
|---|---|
| Metallic area | 157.08 mm² |
| Direct tensile stress W/A | 318.31 MPa |
| Bending stress E_r d_w/D | 179.83 MPa |
| Equivalent bending load σ_b A | 28.248 kN |
| Factor of safety F_u/(W + F_b): use this one | 3.3228 |
| Shigley form (F_u − F_b)/W, only with Shigley's design factors | 4.6350 |
Open this example in the calculator and change any input.
Formula
\(\sigma_t = \frac{W}{A_m}, \quad \sigma_b = \frac{E_r d_w}{D}, \quad n = \frac{F_u}{W + \sigma_b A_m}, \quad n_s = \frac{F_u - F_b}{W}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W\) | Load on the rope (including hook and rope weight) | N |
| \(d_r\) | Rope diameter | m |
| \(A_m\) | Metallic area as a share of the circle πd²/4 | - |
| \(d_w\) | Outer wire diameter | m |
| \(D\) | Sheave pitch diameter | m |
| \(E_r\) | Modulus of the rope | Pa |
| \(F_u\) | Minimum breaking force of the rope | N |
| \(A\) | Metallic area | m² |
| \(\sigma_t\) | Direct tensile stress W/A | Pa |
| \(\sigma_b\) | Bending stress E_r d_w/D | Pa |
| \(F_b\) | Equivalent bending load σ_b A | N |
| \(n\) | Factor of safety F_u/(W + F_b), the one to use | - |
| \(n_s\) | Shigley form (F_u − F_b)/W, only with Shigley's design factors | - |
Method and standards
Reuleaux bending stress of wires over a sheave.
Where it is used
- Hoists and cranes.
- Machine design examinations.
Common mistakes
- Using rope diameter for wire diameter.
- Ignoring rope weight on long lifts.
- Judging Shigley's n_s against the limits meant for n; n_s is always the higher of the two.
Assumptions and limits
Shigley defines the static factor as n_s = (F_u − F_b)/F_t, with F_t the rope tension (W here); it is shown as n_s. The factor n = F_u/(W + F_b) adds the bending load to the tension instead of subtracting it from the strength, and gives a lower (more conservative) figure. Use n for static and bending checks of stationary or general hoisting ropes (50 kN on a 20 mm rope over a 600 mm sheave: n = 3.32). Use n_s (4.63 for the same case) only when working with Shigley's fatigue-adjusted design factors for dynamic, high-speed mine or elevator hoisting.
Static load.
References
- Shigley's Mechanical Engineering Design (Budynas and Nisbett)
- ch. 17 (wire rope, bending stress σ_b = E_r d_w / D)
Questions and answers
What does bending over a 600 mm sheave add for 1.3 mm wires?
180 MPa, equal to 28 kN of extra load on a 20 mm rope.
Why big sheaves?
Bending stress falls as the sheave grows, and fatigue life rises sharply.
Is the static factor enough?
No: fatigue and wear govern rope life; lifting codes set the factors.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.